Vent Termination Requirements - FPI Dell-Point Europa 75 Owners & Installation Manual

Bioenergy stove
Table of Contents

Advertisement

INSTALLATION
IT IS RECOMMENDED THAT YOUR PELLET STOVE BE INSTALLED BY AN AUTHORIZED DEALER/INSTALLER.
The diagram below references all horizontal applications. For vertical applications refer to B365 for Canada and NFPA 211 for the US
along with pages 10 to 13 in this manual.
Min. Clearance
A
84" (2134mm)
Above public walkway, sidewalk or street.
B
72" (1829mm)
Within any gas regulator vent or mechanical air inlet to a building.
C
36" (914mm)
Within a building opening, air inlet of another appliance, an oil tank vent or property boundry
D
36" (914mm)
Horizontally of the vertical centerline of a gas meter/regulator and within height of 15ft. (4.5m) above.
E
12" (305mm)
Above grade level or any non-combustible surface such as cement or gravel.
F
36" (305mm)
To any building projection, adjacent wall or any combustible materials such as grass, trees, fencing, etc.
G
48" (1219mm)
From beside/below any door or window that may be opened.
H
12" (305mm)
Above any door or window that may be opened.
I
12" (305mm)
To inside or outside corner.
J
24" (610mm)
Below any eave or roof overhang.
1. Do not terminate the vent in any enclosed or semi-enclosed areas that can build up a concentration of fumes.
2. Vent surfaces can become extremely hot. Keep children away from such areas. Non-combustible shielding or guards may be required.
3. Termination must exhaust above the inlet elevation. It is recommended to have a short vertical run which will help in the event of total power
failure.
4. If the unit is incorrectly vented or the air to fuel mixture is out of balance, a slight discoloration of the exterior of the house might occur. Since
these factors are beyond the control of FPI we grant no guarantee against such incidents.
5. When installing into an existing masonry chimney, you will probably need a short horizontal section to clear the lintel and allow the hopper lid to
open. See diagram on page 13 for more details.
6. Do not terminate a vent
underneath a veranda porch or deck unless fully open on a minimum of two sides beneath the fl oor.
NOTES:
- Vent terminations shall not be recessed into walls or siding.
- A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings
and serves both dwellings.
- If the vent termination is accessible, a certifi ed guard shall be installed.
- Local codes or regulations such as CAN / CSA B365 or USA NFPA 211 may require different clearances. Check with your local
authorities.