Installation; Important: Save These Instructions; Before You Start; Important Safety Information - FPI Dell-Point Europa 75 Owners & Installation Manual

Bioenergy stove
Table of Contents

Advertisement

IMPORTANT:
SAVE THESE
INSTRUCTIONS
The GF75-1 Stove must be installed in
accordance with these instructions. Carefully
read all the instructions in this manual fi rst.
Consult the building authority having jurisdiction
to determine the need for a permit prior to starting
the installation.
NOTE: Failure to follow the instructions could
cause a malfunction of the heater which could
result in death, serious bodily injury, and/or
property damage.
Failure to follow these
instructions may also void your fi re insurance
and/or warranty.

BEFORE YOU START

It is very important to ensure that the stove is
installed in a safe manner. Be aware of fi re
prevention rules and laws in your area. All
applicable National and Local codes must be
met and complied with.
We recommend that you call an accredited
professional or a dealer trained by FPI to guide
you to install your stove.
Please note the battery back-up comes shipped
inside the Ash pan. Please remove the battery
before start-up.
The stove's electrical connection is to a standard
grounded wall socket. Special care should be
taken so the connection cable is not damaged
in any way.
It is strongly recommended to install a smoke
detector as well as an ABC type extinguisher
near the stove. A power surge bar is also
highly recommended to protect the electrical
component.
If the stove is installed by an uncertifi ed installer,
FPI will not be held responsible for any faulty
operation including poor performance of the
stove.
IMPORTANT SAFETY
INFORMATION
Only use approved fuels in multi-fuel burning
appliances. Failure to comply with this may
create a hazardous situation and will void all
warranties.
In order to start your stove, always use a specifi ed
and approved fi re starter material. Never use
a fl ammable liquid like gasoline, barbecue fi re
starter or alcohol.
GreenFire GF75-1 BioEnergy Stove
Never attempt to re-start your stove until it has
fully cooled down. Never start the stove with a
gel when the burn-pot is hot. This could generate
serious burns. Always wait until the stove is cold
before re-starting it.
Never use or store fl ammable products close to
the stove while it's in use, or at any other time.
Manual feed (Icon 11) is only used to prime the
auger when Hopper is empty. Do not use the
manual feeding procedures to start-up your stove
as these will create smoke in your house.
Ensure that the ash pan door is securely
closed at all times when the stove is in use. Air
pressure could ignite the gas accumulated in the
burn-pot creating an overdraft condition in the
combustion chamber altering the performance
of the burn-pot.
The GF75-1 model will not feed fuel if the main
door is not fully closed and the fi rebox in a
negative pressure situation. This is a safety
function of the appliance.
IMPORTANT:
Stove must be cold before any attempt to
clean the glass is made. Do not use detergent
containing abrasives to clean the windows
or any other parts of the stove. Use only
recommended products found at your local
hearth shop for this type of cleaning.
IMPORTANT:
When cleaning the stove, always remove
ashes into a steel container and place outside
the residence. Use gloves to handle or to
empty the ash pan.
Never use a vacuum cleaner to remove ashes
from the stove, unless you can be sure the
stove is fully cooled down.
IMPORTANT:
Before servicing the electrical panel, make
sure that all electrical source is turned off
to the stove.

INSTALLATION

UNIT LOCATION

1. For optimum benefi t from your appliance,
speak to your professional for help with your
location.
2. The location you choose for your appliance
can be a factor in how it will perform. Choose
an interior location where the vent will not
be affected by any external interference,
i.e. trees, bushes, walls or fencing (refer to
"Vent Termination Requirements" section).
Make sure, at the time of the installation,
that there is the least possible interference
with the existing components of the house.
Install a non fl ammable covering when
necessary. Place the stove according to
recommendations made on "Clearances"
section or according to the safety label fi xed
on the stove.
3. You can use the wall behind the stove to pass
the chimney system or simply join the stove
to an existing chimney or a metal chimney,
with the use of an approved liner.
4. Ensure that all clearances to combustibles
are met as per the safety label and the
diagrams on "Clearances" section.
5. This appliance does not need outside air
unless there is a negative pressure within
the room where the installation takes place.
Make sure that the outside air supply for the
burn-pot does not come from a garage, an
attic or any restricted non-ventilated space.
Air must come from the outside of the house
directly into the room where the stove is
installed.
6. This stove is not approved to be installed
into a bedroom under any circumstances.
7. The fl ooring under the stove must be made
of a non-combustible material, i.e. cement,
ceramics, etc, and must extend at least 6"
(152mm) all around the stove. Refer to the
diagrams on "Clearances" section.
WHAT IS INCLUDED
WITH THE GF75-1
Qty
Description
1 pc
User Manual
1 pc
AC Power Inlet
1 pc
Measuring 2 1/2 Cup Plastic
1 pc
Alligator Clip Black
1 pc
Alligator Clip Red
1 pc
Pipe Adapter Gasket
(for Pressure Reducer Plate)
1 pc
Pressure Reducer Plate 1-1/4 ID
1 pc
Pressure Reducer Plate 1-5/8 ID
1 pc
Poker
1 pc
12-V Battery
1 pc
Battery Cage
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greenfire gf75-1

Table of Contents