Installation And Configuration WARNING: Before performing the following procedure, review the safety instructions that came with the system. Unpacking A Rack System Unpack your system and identify each item. Assemble the rails and install the system in the rack following the safety instructions and the rack installation instructions provided with your system.
Optional—Connecting The Keyboard, Mouse, And Monitor Figure 2. Connecting the Keyboard, Mouse, and Monitor Connect the keyboard, mouse, and monitor (optional). The connectors on the back of your system have icons indicating which cable to plug into each connector. Be sure to tighten the screws (if any) on the monitor's cable connector.
Connect the system’s power cable to the system and, if a monitor is used, connect the monitor’s power cable to the monitor. Securing The Power Cable(s) Figure 4. Securing the Power Cable(s) Bend the system power cable(s), as shown in the illustration, and attach to the cable strap.
If you do not accept the terms of the agreement, call the customer assistance telephone number. For customers in the United States, call 800-WWW-DELL (800-999-3355). For customers outside the United States, visit support.dell.com and select your country or region from the top of the page.
If you do not understand a procedure in this guide or if the system does not perform as Owner’s Manual . Dell offers comprehensive hardware training and expected, see your certification. See dell.com/training for more information. This service may not be offered in all locations. NOM Information (Mexico Only)
Unit) Technical Specification NOTE: The following specifications are only those required by law to ship with your system. For a complete and current listing of the specifications for your system, go to support.dell.com. Power AC Power Supply (per power supply)
Page 9
Weight (empty) 16.33 kg (36 lb) Environmental NOTE: For additional information about environmental measurements for specific system configurations, see dell.com/environmental_datasheets. Temperature Operating Continuous operation: 10 °C to 35 °C at 10% to 80% relative humidity (RH), with 26 °C max dew point.
Page 10
Environmental Maximum shock Operating One shock pulse in the positive z axis (one pulse on each side of the system) of 31 G for 2.6 ms in the operational orientation Storage Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on...