FULL SIZE GAS CONVECTION OVENS - ELECTRICAL OPERATION
Temperature Probe . . . . . . . . . . . . Senses the oven temperature for the solid state temperature control or the
Gas Valve (Dual Solenoid) . . . . . . . Allows gas flow to the burner when the 1
Cooling Fan . . . . . . . . . . . . . . . . . . . Circulates cooler air from rear of oven forward to cool components in the
Mechanical Temperature Control
KX Thermostat (WKG/WKGX) . . . . Regulates the oven cavity temperature by controlling the heat relay (R3)
Hold Thermostat (KX) . . . . . . . . . . Holds the oven cavity temperature at 160°F after ROAST (then hold) time

COMPONENT LOCATION

F32700 (February 2006)
computer control. On WKGD/WKGDX models, converts the temperature
into a resistance valve which is monitored by the temperature control board.
The probe is an RTD (resistance temperature detector) of the Thermistor
type. As temperature increases the resistance value decreases.
On WKGC/WKGCX models, the probe is a J type thermocouple.
(main) solenoid coils are both energized.
control area.
through the blower motor centrifugal switch contacts. On ROAST & HOLD
models only, power is first connected through one set of (R4) normally
closed contacts (N.C.) then through the centrifugal switch contacts on the
motor.
expires. For the oven to operate on the Hold thermostat, the ROAST &
HOLD timer must be used and the Function Switch (S3) must be set to.
Available on models with Roast & Hold option only.
Page 30 of 64
st
nd
valve (safety) and 2
valve