5.
Reverse procedure to install.
TEMP (°F)
OHMS*
77
90000
240
4077
260
3016
280
2266
300
1726
320
1332
340
1041
(*) Resistance in ohms ± 10%

GAS PRESSURE ADJUSTMENT

WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
WARNING: SHUT OFF THE GAS BEFORE
SERVICING THE UNIT.
1.
Remove the right side panel as outlined under
COVERS AND PANELS in REMOVAL AND
REPLACEMENT OF PARTS.
NOTE: If right side panel is not accessible, this
component can be serviced by removing the control
panel as outlined under COVERS AND PANELS.
2.
Remove the plug from the manifold pressure
port.
3.
Install hose barb adapter and attach manometer
tube.
TEMP (°F)
OHMS*
360
822
380
656
400
529
425
424
450
334
475
266
Page 21 of 64
4.
Remove adjustment screw cap from the gas
valve and turn gas supply to the oven back on.
5.
Plug the unit in and turn the power switch ON.
6.
Set the temperature control to its highest setting
and allow burner to ignite.
NOTE: Accurate gas pressure adjustments can only
be made with the gas on and the burner lit.
7.
Turn the set screw to obtain the proper gas
pressure (clockwise = pressure increase;
counterclockwise = pressure decrease).
PRESSURE READINGS (IN W.C.)
GAS
MANIFOLD
TYPE
RECOMMENDED MIN MAX
3.5
Natural
Propane
10
NOTE: If the incoming line pressure to the valve is
less than the minimum stated, then the manifold
pressure can not be set correctly.
LINE
7
5
14
11
11
F32700 (February 2006)