the value, it does not take effect.
1
: change behavior type
2
: change behavior interval
3
: change threshold boundary level
4
: change custom unit
5
: change custom time base
6
: change custom low
7
: change custom high
8
: change custom buffer
9
: apply threshold boundary changes
10 : cancel threshold boundary changes
Select choice => : (1..18) [18] 3
1
: Default
2
: custom
Enter boundary level type => : (1..2) [1] 2
Index ThresholdName
8 eportRXPerf008
17 eportRXPerf017
26 eportRXPerf026
27 eportRXPerf027
28 eportRXPerf028
29 eportRXPerf029
Threshold boundary level is set at : Custom
.
.
.
1
: change behavior type
2
: change behavior interval
3
: change threshold boundary level
4
: change custom unit
5
: change custom time base
6
: change custom low
7
: change custom high
8
: change custom buffer
9
: apply threshold boundary changes
10 : cancel threshold boundary changes
Select choice => : (1..18) [18] 9
.
.
.
NOTE:
To ensure that your threshold setting configuration takes effect, remember to apply the threshold
boundary changes, and then change the threshold boundary level to Custom.
Table 14
describes the event behavior of each element in the Threshold Boundary menu.
Table 14

Element listing information - threshold boundary menu

Heading
Default
Custom
See
"Fabric watch
methods for each of the possible event settings.
For details about advanced configuration menu options, see
40
Configuring Fabric Watch
BehaviorType
Triggered
Triggered
Triggered
Triggered
Triggered
Triggered
Meaning
The Fabric OS default settings
User-defined settings
components" on page 19 for more details about the event setting table and notification
11 : change threshold alarm level
12 : change changed alarm
13 : change below alarm
14 : change above alarm
15 : change inBetween alarm
16 : apply threshold alarm changes
17 : cancel threshold alarm changes
18 : return to previous page
BehaviorInt
1
1
1
1
1
1
11 : change threshold alarm level
12 : change changed alarm
13 : change below alarm
14 : change above alarm
15 : change inBetween alarm
16 : apply threshold alarm changes
17 : cancel threshold alarm changes
18 : return to previous page