Very slow product performance (Running as RAID5 access to the disks, if the arrays had not
failed themselves)
Refusal to create the storage (if the storage arrays have failed and need to be rebuilt from
scratch)
The units are shipped with paper copies of the SAAP license. If you no longer have this license
and the board is still working, make a note of the license before you replace the motherboard.
1.
Reboot the system.
2.
During the POST screen, when advised, hit any key to see further messages.
3.
Enter the Smart Array POST ORCA utility by pressing [F8] when advised during the POST
messages.
4.
Select the Manage Licenses option in the Smart Array menu, and then select View Licenses.
5.
Make a note of the licence key reported. This key is unique to the system and can be used
for any replacement Smart Array card (or HP D2D4312 motherboard).

J27 settings (HP D2D4106/41 12 G2 and HP D2D2502/2504 G2)

NOTE:
This section is not relevant for HP D2D4324/4312 models.
The following diagram shows the location of the J27 jumper on the motherboard.
Figure 13 Location of the J27 jumper
1
J27 jumper
When replacing the motherboard on HP D2D4106/41 12 G2 models or on HP D2D2502/2504
G2 models, set the jumper as follows.
20
Replacing the system motherboard