Goodman GPG13 Installation & Operating Instructions Manual page 28

Gpg13 series single package gas-electric heating & cooling unit
Table of Contents

Advertisement

L1
SUPPLY VOLTAGE
208-230/3/60
NOTE 3
C
T2
T1
T1
L1
COMP
T3
FC
IIC
C
L1
H
L1
L1
D1
L1
3
1
F
FS
4
5
ALS
3
IIC
6
8
E C O N
9
7
10
12
11
R
G
W
Y1
Y2
TO THERMOSTAT
INSTALLER/SERVICEMAN
THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO
TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:
STATUS LIGHT
EQUIP. ST ATUS
ON
NORMAL OPERATION
NO POWER OR
OFF
INTERNAL CONTROL
FAULT
IGNITION FAILURE
1 BLINK
OR
OPEN ROLLOUT
SWITCH
OR
OPEN AUX. LIMIT
SWITCH
PRESSURE SWITCH
2 BLINKS
OPEN
PRESSURE SWITCH CLOSED
3 BLINKS
WITHOUT INDUCER ON
OPEN LIMIT SWITCH
4 BLINKS
5 BLINKS
FALSE FLAME SENSED
6 BLINKS
COMPRESSOR
OUTPUT DELAY
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.
GPG13(36)3A WIRING DIAGRAM
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
L2
CH
C
T3
T2
L2
C
C
F
FC
CM
(MED)
NOTE 4
EM
L2
VM
L2
2
1
L2
NOTE 2
TR
IGN
FS
LS
RS
GV
PS
C
NOTE 5
PLF
Y
C
CHECK
-
CHECK INPUT POWER
C HE C K FU S E O N C O N TR O L
REPLACE CONTROL
GAS FLOW
GAS PRESSURE
GAS VALVE
FLAME SENSOR
FLAME ROLLOUT
BAD SWITCH
AUX. LIMIT OPEN
CHECK
PRESSURE SWITCH
CHECK
PRESSURE SWITCH
MAIN LIMIT OPEN
BAD SWITCH
STICKING GAS VALVE
3 MIN. COMP.
ANTI-CYCLE TIMER
L3
COMPONENT LEG END
ALS
AUXILLARY LIMIT SWITCH
COMP
COMPRESSOR
CM
CONDENSER MOTOR
L3
C
CONTACTOR
CH
CRANKCASE HEATER
EM
EVAPORATOR MOTOR
F
FUSE
FC
FAN CAPACITOR
FS
FLAME SENSOR
GND
EQUIPMENT GROUND
GV
GAS VALVE
IIC
INTEGRATED IGNITION CONTROL
IGN
IGNITOR
LS
LIMIT SWITCH
PLF
FEMALE PLUG/CONNECTOR
PS
PRESSURE SWITCH
2
RS
ROLLOUT SWITCH
TR
TRANSFORMER
VM
VENT MOTOR
NOTES
1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF
INSULATION AS ORIGINAL.(USE COPPER CONDUCTOR ONLY).
2. FOR 208 VOLT TRANSFORMER OPERATION MOVE BLACK WIRE
FROM TERMINAL 3 TO TERMINAL 2 ON TRANSFORMER.
3. CRANKCASE HEATER NOT SUPPLIED ON ALL UNITS.
4. FOR DIFFERENT THAN FACTORY SPEED TAP. CHANGE CO OLING
SPEED AT COOL TERMINAL (IIC). CHANGE HEATING SPEED AT HEAT
TERMINAL (IIC)
3 SPEED MOTOR
BK - HIGH SPEED
BL - MEDIUM SPEED
RD - LOW SPEED
6
5
4
5. ACCESSORY ECONOMIZER PLUG (ON SELECT MODELS) ADJACENT
3
2
1
TO BLOWER HOUSING IN RETURN AIR COMPARMENT.
6. USE COOPER CONDUCTORS ONLY.
USE NEC CLASS 2 WIRE.
THERMOSTAT FIELD WIRING
NO ECONOMIZER
WH
GR
RD
YL
BL
WITH ECONOMIZER OPTION
WH
GR
RD
PU
BL
28
FACTORY WIRING
LINE VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH VOLTAGE
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
WIRE CODE
BK BLACK
BL BLUE
BR BROWN
GR G REEN
OR O RANGE
PK PINK
PU PURPLE
RD RED
WH WHITE
YL YELLO W
208-230/3/60
2 STAGE COOLING
WH
W
GR
G
RD
R
PU
Y
YL
C
BL
W
G
R
Y
C
0140G00085P
W
G
R
Y1
Y2
C