The MOBILELOCK
TM
unit will not function without power. If the
internal battery has not been adequately charged, the product will
not operate. When the low battery notification is received, the alka-
line batteries are completely discharged and the MOBILELOCK
unit's internal rechargeable battery is low. Change the batteries
within 24 hours to limit vulnerability. Several factors such as cellu-
lar signal strength, number of location requests, number of alarms,
and other activities affect the battery run-time.
DS510
The battery is intended to last several years. To ensure proper
security, replace the battery every 12 months.
IMPORTANT: Once an alarm condition is signaled, further alarms
are inhibited until no motion is sensed for a period of more than
90 seconds. This feature is designed to conserve battery life by
ignoring the normal occurrence of motion throughout the day.

STATUS UPDATE AND SYSTEM TEST

It is recommended to test the system periodically. This system test
will test each of the active sensors.
Go online to www.dewalt.com/mobilelock or call the phone menu
system (1-410-329-9477) to perform a system test.
NOTE: The MOBILELOCK
to change.
TO COMPLETE THE SYSTEM TEST THROUGH THE WEBSITE
1. Go online to www.dewalt.com/mobilelock and enter login and
password.
2. Select Unit Customization .
3. Select unit.
4. Select System Test. The MOBILELOCK
Page 16
TM
website and phone menu is subject
TM
unit will cycle through
all the ACTIVE sensors in the following order: vibration, door
contact, motion, and tamper. As you trip each sensor, the
MOBILELOCK
TM
unit will sound an alarm. A cellular notification
will not be sent. Continue tripping sensors until the test is
complete. The test will automatically time out after 5 minutes or
TM
when each of the sensors has been tripped.
TO COMPLETE THE SYSTEM TEST THROUGH
THE PHONE MENU
1. Call 1-410-329-9477 and enter login and password.
2. Select Unit Maintenance from the main menu.
3. Select Status Update followed by System Test.
4. Status will offer the following information:
• Armed/disarmed/scheduled
• Battery level
• Cellular signal strength
• Sensor settings
• Alarm siren setting
5. Select Perform a System Test . The MOBILELOCK
cycle through all the ACTIVE sensors in the following order:
vibration, door contact, motion, and tamper. As you trip each
sensor, the MOBILELOCK
notification will not be sent. Continue tripping sensors until the
test is complete. The test will automatically time out after
5 minutes or when each of the sensors has been tripped.

Specifications

Power
Battery capacity
Operating temperature
16
TM
unit will
TM
unit will sound an alarm. A cellular
120 V AC into power supply
4400 mAH @ 4.65 V typical
-4˚ to 122˚F (-20˚ to 50˚C)