Download Print this page

Technical Specification - Foster Display Case Parameter Settings Service Manual

Display case service manual

Advertisement

Cooling Rate
Compressor Difference
Condenser Overheat Folder
Alarm Temperature
Alarm Temperature Delay
Shutdown Temperature
Shutdown Temperature Delay
Net Folder
Device Identification
Thermostat Probe Calibration
Return NRC-100 Default settings
NOTE: Not Cabinet Settings
*) Calibration according to factory test run.
**) Gas Defrost = 1
***) Gas defrost = 0
****) Gas defrost = 15

Technical Specification

Model
Compressor cm3
PREM 125
15 + 15
PREM 195
18 + 18
PRO 90
18
PRO 130
21
PRO 195
14 + 14
SLIM 70
10
SLIM 90
14
SLIM 120
18
MINI 90
14
MINI 120
18
* For cabinets with 2 compressors fitted there is a 20 second delay between compressor starts so the start current of 20A is not exceeded.
The suction pressure as per climate class 3 (see below) is between -8 and -10 ºC approximately 3.5 bar, with a discharge temperature of +40 ºC (clean condenser)
approximately 17.3 bar.
The cases are designed to work in an ambient temperature not exceeding 25 degrees centigrade (C) with a relative humidity not exceeding 60% (RH) Climate Class 3.
The frontal airflow should be < 0,2m/s
Probes
The probes used are PT-1000 with rating at 0º C of 1000 Ohms. There is not a temperature range but the resistance value is approximately 950 Ohms at - 10º C and 1200
at + 50º C.
%
rAtE
70
70
2dlF
2
2
(OH)
ºC
AL
50
50
min
Alt
2
2
ºC
Sd
55
55
min
Sdt
0
0
(nEt)
nlD
0
0
-*
-*
CAL1
-
-
-
SdFt
Total Power Input (W)
(Thermal Heat Rejection)
2022
2934
1688
2058
2954
1248
1468
1710
1414
1684
70
70
70
70
2
2
2
2
50
47
47
47
2
2
2
2
55
52
52
52
0
0
0
0
0
0
0
0
-*
-*
-*
-*
-
-
-
-
Compressor Run
Run Amps
Watts
10.8
1360
14.8
1800
8.3
900
9.9
910
14.8
1360
6.4
460
7.4
680
8.4
900
7.1
680
8.3
900
7
70
70
70
70
2
2
2
2
50
50
50
50
2
2
2
2
55
55
55
55
0
0
0
0
0
0
0
0
-*
-*
-*
-*
-
-
-
-
Compressor
Fuse
Start Current
20A*
13A
20A*
16A
20A
13A
20A
13A
20A*
16A
20A
13A
20A
13A
20A
13A
20A
13A
20A
13A
70
70
70
2
2
2
47
47
47
2
2
2
55
55
55
0
0
0
0
0
0
-*
-*
-*
-
-
-
kWh/24h
dB (A)
43.0
<59
63.2
<59
35.8
<59
43.9
<59
63.7
<59
25.5
<56
30.1
<56
35.1
<56
29.5
<56
35.3
<56