Environmental Management Policy for Service Manuals and Duets. Product Support and Installation Contractors Foster Refrigerator recognises that its activities, products and services can have an adverse impact upon the environment. The organisation is committed to implementing systems and controls to manage, reduce and eliminate its adverse environmental impacts wherever possible, and has formulated an Environmental Policy outlining our core aims.
Thermostat probe failure. Call your Foster Authorised Service Company. Evaporator probe failure. Call your Foster Authorised Service Company. Air probe temperature failure. Call your Foster Authorised Service Company. Safety switch probe failure. Call your Foster Authorised Service Company. Safety switch probe failure. Call your Foster Authorised Service Company.
Information Menu Pressing and releasing FNC will access the information menu, use the UP or DOWN keys to scroll through and press OK to display the value. The first in the menu is Sett; this indicates the set value, press OK to display the value. Release OK and Nd will be displayed;...
Drying time after the termination of a defrost The group 2 values are only used on selected models. Service Menu Settings folder (Set) SetC Parameter List Set point value group for user menu 1 and 2 UloC Keyboard Lock Locks the controller and disables the user menu and manual defrost. Set Point Value Set point for the first control settings Lower Set Limit...
Page 6
C2PD Condenser Overheat Probe 1 Selects the probe used. Compressor Folder (CP) Defrost Mode Selects the type of defrost used 0 = Electrical Defrost; 1 = Hot gas defrost L on Min. Working Time Minimum working time for the compressor H on Max.
Page 7
Foster Display Case Parameter Settings NRC100 MINI MINI MINI MINI Slim Slim Slim FPREM FPREM FPRO FPRO FPRO Model Default FM90 FM120 FM90 FM120 FS70 FS90 FS120 125HG 195HG 90HG 130HG 195HG C1.0-15/08 130HG 130HG 150HG 150HG User Menu Temperature Set Point 1...
Case Faults and Possible Solutions Problem Possible Cause Solution Display Shows Probe Failure, Probe with the same number broken or has a bad connection Check connection or change ERR1 1 = Thermostat Probe probe. ERR2 2 = Defrost Probe ERR3 3 = Cabinet Probe ERR4 4 = Condenser Overheat Probe...