Horstmann ChannelPlus H37VXL Series 2 User Operating Instructions Manual

Horstmann ChannelPlus H37VXL Series 2 User Operating Instructions Manual

Three channel central heating and hot water programmer

Advertisement

ChannelPlus H37VXL Series 2
User Operating Instructions
Three Channel Central Heating and Hot Water Programmer
The ChannelPlus family of electronic programmers offer a range of advanced features
coupled with simplified 'menu driven' programming all designed to help save energy.
The Horstmann ChannelPlus H37VXL series 2 is designed to give independent time control
over 3 channels of heating or hot water on a 7 day weekly programme.
Each channel offers up to 3 programmed On/Off operations per day
for each day of the week.
For day to day operation each channel has a manual 1 or 2 hour boost button
as well as an advance button to bring forward the next programmed operation.
The back lit display, automatic clock and menu driven programming are all features
designed to make the operation of the ChannelPlus H37VXL as simple as possible to use.
All series 2 ChannelPlus programmers are direct replacements for earlier ChannelPlus models.
1

Advertisement

Table of Contents
loading

Summary of Contents for Horstmann ChannelPlus H37VXL Series 2

  • Page 1 The ChannelPlus family of electronic programmers offer a range of advanced features coupled with simplified ‘menu driven’ programming all designed to help save energy. The Horstmann ChannelPlus H37VXL series 2 is designed to give independent time control over 3 channels of heating or hot water on a 7 day weekly programme.
  • Page 2 The ChannelPlus H37VXL Series 2 Programmer The simple instructions contained in this user guide are designed to help with the programming and operation of the unit. Most of the following instructions require the front flap to be lowered. Please replace the flap when normal operation is required. PRODUCT OVERVIEW - DETAIL SHOWN WITH THE FLAP LOWERED Current time of day Day of week and date...
  • Page 3: Display Information

    Display Information Holiday function The ChannelPlus H37VXL Series 2 Time active Date programmer has a fully graphical, back- lit display. In the normal run mode the display is divided into 3 sections, each section represents a controlled channel. The information displayed will change Channel depending upon the settings made and header...
  • Page 4: Manual Overrides

    Manual Overrides BOOST FUNCTION - 1 OR 2 HOUR TEMPORARY OVERRIDE The boost facility will allow the user to either activate a channel which is currently ‘OFF’ for 1 or 2 hours, or to extend a current ‘ON’ period by 1 or 2 hours. To indicate the boost being activated the ‘BOOST’...
  • Page 5 Programme Override Facilities With the ChannelPlus H37VXL Series 2 programmer operating in the normal running mode it is possible to alter the functionality of the programme on each individual channel by means of the blue ‘select’ buttons under the front flap. The options include;...
  • Page 6 Setting the Programme Times The programme times have been preset as shown in the chart below. DEFAULT TIME SETTINGS - AM/PM 1st ON 1st OFF 2nd ON 2nd OFF 3rd ON 3rd OFF Mon - Fri 6.30AM 8.30AM 12.00PM 12.00PM 4.30PM 10.30PM Sat/Sun...
  • Page 7: Setting The Holiday Mode

    Setting the Holiday Mode The holiday mode can be used to suspend the program function of the ChannelPlus programmer, it can be set in advance of your departure date and for as long a period as required. The holiday function operates from mid-day to mid-day, this means it can be easily set to ensure your home is warm for your return.
  • Page 8: Adjusting Default Settings

    Adjusting Default Settings The ChannelPlus H37VXL Series 2 has a number of default settings which are normally installed. These settings are designed to reduce the need for user intervention upon installation of the programmer. However it is possible to customise the user display by following the procedures in the following pages.
  • Page 9: Adjusting Time And Date

    Adjusting Time and Date The ChannelPlus H37VXL Series 2 programmer has been set with the current time and date during manufacture. No alteration should be required to the time and date, however if any modification is required please refer to the flowchart below. PLEASE NOTE: Any alteration to the current time or date will cancel any Holiday programme set.
  • Page 10: General Information

    Adjusting Clock Options The programmer has been preset to display the time in 24 hour Open cover clock format, should you prefer AM/PM format then please use the procedure given in the flowchart opposite. Use the ‘+’ and ‘-’ Press the green ...
  • Page 11: Reset Procedure

    Adjusting Channel Headings The programmer has been preset to display the channel heading Open cover as ‘Heating and Hot Water’, should you require either the ‘Zone’ or ‘Channel’ options then please follow the flowchart opposite. Use the ‘+’ and ‘-’ Press the green ...
  • Page 12 Email: sales@horstmann.co.uk Website: www.horstmann.co.uk Horstmann Controls Limited, Bristol BS4 1UP Leaflet number P82724 – Issue 2...

Table of Contents