Craftsman HYDROGLASS 390.2511 Owner's Manual page 7

Convertible deep well jet pump
Hide thumbs Also See for HYDROGLASS 390.2511:
Table of Contents

Advertisement

INSTALLATION
STEEL PIPING
INSTALLATIONS
When
steel pipe
is used
to install the jet, be sure
all pipes
are clean
and the ends are reamed.
Screw
both
1-1/4" NPT
suction
pipe and 1" NPT drive pipe directly
into the jet body.
The special
adapter
nipple
furnished
with the jet is not used
on steel pipe installations,
and should
be discarded.
Add suf-
ficient
piping,
using
pipe
thread
compound
on the joints
until proper
depth
is reached.
NOTICE:
Pipe compound
can damage
plastic
components
in pump.
Use only Teflon tape or Plasto-Joint
Stik _when
con-
necting
pipe to pump.
SINGLE
PIPE JETS - 2" OR 3" WELLS
Before
installing
jet in well,
it is necessary
to soften
jet
leathers
by soaking
in water
for a minimum
of one hour.
Single pipe
jets must
be installed
with steel suction
piping
in the well.
Make
sure
all pipes
are clean
and
ends
are
reamed
before
lowering
any
piping
into
the well.
Look
through
pipe to make certain
there
are no obstructions.
During
the process
of lowering
pipe into the well, always ifi-
stall coupling
on top end of pipe and above
clamp.
This will
prevent
accidental
dropping
of pipe into well.
Attach the jet to the first length
of suction pipe 1-1/4" (NPT).
Use turned
couplings
(furnished)
on 2" wells. Standard
cou-
plings
may be used for suction
piping
on 3" wells. Use pipe
compound
on male threads
only.
Tighten
each length
of pipe
as it is lowered
into the well.
Lower
it to proper
depth
which
is 10-15 feet below
the
drawdown
water
level. This is the level to which
the water
will drop wbSfle the well is being pumped
continuously.
NOTICE:
Due to normal
irregularities
in the leather
of the
cup seals and the inner
walls of the drop pipe, 2" packer
jets
do not form
a perfect
seal. In a dormant
system,
water
will
leak back into well over time and pump
vdll normally
start
and cycle to maintain
system
pressure
level.
PRIMING
PIPE (OR PIPES) IN WELL
Fill piping
in well with water
as each length
is added,
or after
piping
is complete
in well. This serves
to double
check
for
leaks in piping
and foot valve, and simplifies
final priming
of
pump.
INSTALLING
CASING
ADAPTER
Slide adapter on to well casing as far as it will go. Tighten
three bolts to seal the adapter to the casing. Place a 1" nip-
pie of proper length in the drive pipe opening in the casing
adapter, and tighten top nuts. This v_dl seal the glands on to
both suction and drive piping. Add elbows and flexible pipe
adapters for horizontal
installations.
'Lake ChemlcaI
Co., Cblcago,
Illinois.
SHALLOW
WELL
INSTALLATION
AND
OPERATION
Install_g
the Pump
on a Shallow
Well
A shallow
well jet is available
for use when
the SEARS jet
pump
is installed
on wells 20 feet or less to drawdown
water
level.
install
this jet as follows:
a.
Loosen the stainless
steel clamp
until it fits over the flange
on the jet body.
b. Place O-Ring in circular
groove
on face of suction<lfive
line flange,
ff necessary,
use petroleum
jelly to hold in
place.
c.
Venturi
that protrudes
from the jet body must be inserted
in top (1-1/4" _
tapping.
For ease of assembly,
lubri-
cate the small O-Ring on the end of the venturi
and push
the shallow
well jet assembly
into place.
d. Align lugs on jet body with
slots in pump.
e.
Place clamp
over the flanges
and tighten
securely.
For standard
tank installations,
an air volume
control
is nec-
essary and is connected
to the 1/8" tapping
in the jet body.
Connect
as shown
in installation
drawing,
Figure 4, Page 5.
PIPING
IN THE WELL
A shallow
well jet pump
can be installed
on a dug well,
drilled
well or with
a driven
point.
SEARS shallow
well jet
pumps
have a built-in
check
valve. In a dug or cased well, a
foot valve
and strainer
is recommended
and should
be in-
stalled 5 to 10 feet below
the lowest
level to which
the water
vdll drop
while
the pump
is operating
(pumping
water
level). See Figure 4, Page 5. Your well driller can furnish
this
information.
The strainer
should
not be too close to the bot-
tom, or sediment
may clog it. Before installing
foot valve,
check to see if it works
freely.
When
using a foot valve, a priming
tee and a plug as shown
in Figure 7 is recommended.
Figure 7