Please notethefollowing:
Thesystem shouldbeinstalled onlywithpiping thatis
suitable forpotable (drinkable) watersuchas copper,
CPVC, o r polybutylene. Thiswaterheater m ustnotbe
installed usingironpiping or PVCwaterpiping.
Useonlypumps, v alves, o rfittings thatarecompatible
withpotable water.
Useonlyfullflowballor gatevalves. T heuseof valves
thatmaycauseexcessive r estriction t owaterflowis
notrecommended.
Useonly95/5tin-antimony orotherequivalent solder.
Anyleadbased solder mustnotbeused.
Piping thathasbeentreated withchromates, boiler
seal,orotherchemicals m ustnotbeused.
Chemicals t hatmaycontaminate t hepotable water
supply mustnotbeadded tothepiping system.
Closed System/Thermal
Expansion
Explosion
Hazard
If the temperature
and pressure
relief valve
is dripping
or leaking,
have a qualified
person replace
it.
Examples
of a qualified
person include:
licensed
plumbers,
authorized
gas company
personnel,
and authorized
service
personnel.
Do not plug valve.
Do not remove valve.
Failure to follow these instructions
can
result in death, or explosion.
As water is heated, it expands (thermal expansion). In
a closed system, the volume of water will grow. As the
volume of water grows, there will be a corresponding
increase in water pressure due to thermal expansion.
Thermal expansion can cause premature tank failure
(leakage). This type of failure is not covered under the
limited warranty. Thermal expansion can also cause
intermittent temperature-pressure
relief valve operation:
water discharged from the valve due to excessive pressure
build up. The temperature-pressure
relief valve is not
intended for the constant relief of thermal expansion. This
condition is not covered under the limited warranty.
A properly-sized
thermal expansion tank should be
installed on all closed systems to control the effects of
thermal expansion.
Contact a plumbing service agency or
your retail supplier regarding the installation of a thermal
expansion tank.