™ Sun StorageTek PCI Express Enterprise 4 Gb FC Host Bus Adapters Emulex Installation Guide Sun Microsystems, Inc. www.sun.com Part No. 819-4810-10 December 2005, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback...
Page 2
Copyright 2005 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved. Sun Microsystems, Inc. has intellectual property rights relating to technology that is described in this document. In particular, and without limitation, these intellectual property rights may include one or more of the U.S. patents listed at http://www.sun.com/patents and one or more additional patents or pending patent applications in the U.S.
To Verify Attached Storage to the Installed HBA 12 Installing the HBA Driver with the Solaris 10 OS 14 Packages 14 Patches 15 Sun Product Information Page at Emulex 15 Diagnostic Support 16 Declaration of Conformity, Regulatory Compliance, and Safety Statements 17...
Page 4
Declaration of Conformity 19 Regulatory Compliance Statements 21 Safety Agency Compliance Statements 25 Sun StorageTek PCI Express Enterprise 4 Gb FC HBA Emulex Installation Guide • December 2005...
Preface This guide describes how to install the Sun StorageTek™ Enterprise PCI Express 4 Gb Fibre Channel (FC) Single and Dual Port Host Bus Adapter (HBA). It also explains how to update the driver. How This Book Is Organized The single chapter describes how to install the HBA and update the driver. Appendix A provides the safety, regulatory, and compliance information for the product.
* The settings on your browser might differ from these settings. Related Documentation Application Latest information Locating documents vi Sun StorageTek PCI Express Enterprise 4 Gb FC HBA Emulex Installation Guide • December 2005 Meaning The names of commands, files, and directories; on-screen computer output...
Accessing Sun Documentation You can view, print, or purchase a broad selection of Sun documentation, including localized versions, at: http://www.sun.com/documentation Third-Party Web Sites Sun is not responsible for the availability of third-party web sites mentioned in this document. Sun does not endorse and is not responsible or liable for any content, advertising, products, or other materials that are available on or through such sites or resources.
Please include the title and part number of your document with your feedback: Sun StorageTek PCI Express Enterprise 4 Gb FC HBA Emulex Installation Guide, part number 819-4810-10 viii Sun StorageTek PCI Express Enterprise 4 Gb FC HBA Emulex Installation Guide • December 2005...
“Installing the HBA” on page 2 ■ “Installing the HBA Driver with the Solaris 10 OS” on page 14 ■ “Sun Product Information Page at Emulex” on page 15 ■ “Diagnostic Support” on page 16 ■ Caution – Be sure to keep the Sun StorageTek PCI Express Enterprise 4 Gb FC Single and Dual Port HBA in the antistatic bag until installation.
To Install the HBA Hardware ▼ To install the Sun StorageTek PCI Express Enterprise 4 Gb FC HBA Emulex, you need to open the computer and identify an empty PCI Express 4 lane slot. If necessary, consult your computer system manual for instructions to remove the computer cover.
Page 12
Replace the screws that attach the HBA to the bracket. 6. Insert the HBA into the empty PCI Express 4-lane slot. Press firmly until the adapter is seated. Sun StorageTek PCI Express Enterprise 4 Gb FC HBA Emulex Installation Guide • December 2005 FIGURE 2...
7. Secure the HBA’s mounting bracket to the case with the panel screw or clip. 8. Replace the computer case and tighten the case screws. The HBA is now installed in the computer and is ready for the optical cable attachment.
Page 14
Attaching the Optical Cable FIGURE 3 2. Connect the other end of the cable to the Fibre Channel device. Sun StorageTek PCI Express Enterprise 4 Gb FC HBA Emulex Installation Guide • December 2005 Yellow LED State 2 Fast Blinks 2 Gb Link Rate –...
After the optical cable is connected to the HBA, you are ready to apply power to the computer. ▼ To Apply Power 1. Verify that the HBA is securely installed in the computer. 2. Verify that the correct optical cable is attached. 3.
If online storage is connected to the HBA, use the apply show-children command to list the attached storage. Sun StorageTek PCI Express Enterprise 4 Gb FC HBA Emulex Installation Guide • December 2005 82080110 00000000 03504000 00000000 82080118 00000000 03506000 00000000 00002000...
Page 21
In the example that follows, a storage JBOD has twelve targets attached to one port of the dual-ported HBA. {0} ok apply show-children Device ALPA b6 WWPN 215000c0ff00223d ESI Device Link attention Device ALPA b9 WWPN 2100000c50c30555 Disk Device ALPA ba WWPN 2100000c50c30525 Disk Device...
5. Click the download item that is appropriate for this 4 Gbit adapter The following packages are contained in the zipped file: Sun StorageTek PCI Express Enterprise 4 Gb FC HBA Emulex Installation Guide • December 2005 File Name s10_emlxs_pkgs.tar.Z...
3. Under Patches and Updates, click PatchFinder. 4. Download the following patch by typing the patch ID (without the dash number) in the Enter Patch ID box and click Find Patch. 120222-06 (or above) SunOS 5.10: Emulex-Sun Fibre LightPulse Channel Adapter ■ driver 5.
Diagnostic support for the Sun StorageTek PCI Express Enterprise 4 Gb FC HBA Emulex is available with SunVTS™ 6.0 plus apply patch number 119838-03 or above. Sun StorageTek PCI Express Enterprise 4 Gb FC HBA Emulex Installation Guide • December 2005...
A P P E N D I X Declaration of Conformity, Regulatory Compliance, and Safety Statements This appendix contains the following information that applies to the Sun StorageTek PCI Express 4 Gb Fibre Channel Single and Dual Port Host Bus Adapter: “Declaration of Conformity”...
Page 26
Sun StorageTek PCI Express Enterprise 4 Gb FC HBA Emulex Installation Guide • December 2005...
Compliance Model Number: LPe-XXXX Product Family Name: Emulex 4GB FC Single and Dual Port PCI-Express Host Bus Adapter (SG-XPCIE1FC-EM4, SG-XPCIE2FC-EM4) USA - FCC Class A This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This equipment may not cause harmful interference.
Page 28
Sun StorageTek PCI Express Enterprise 4 Gb FC HBA Emulex Installation Guide • December 2005...
Regulatory Compliance Statements Your Sun product is marked to indicate its compliance class: • Federal Communications Commission (FCC) — USA • Industry Canada Equipment Standard for Digital Equipment (ICES-003) — Canada • Voluntary Control Council for Interference (VCCI) — Japan •...
Page 30
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. Graphic showing the Japanese VCCI-A regulatory statement Graphic showing the Japanese VCCI-B regulatory statement Sun StorageTek PCI Express Enterprise 4 Gb FC HBA Emulex Installation Guide • December 2005...
BSMI Class A Notice The following statement is applicable to products shipped to Taiwan and marked as Class A on the product compliance label. Graphic showing the BSMI Class A Notice for products shipped to Taiwan D33012 Graphic showing the BMSI Declaration of Conformity mark CCC Class A Notice The following statement is applicable to products shipped to China and marked with “Class A”...
Page 32
GOST-R Certification Mark Graphic showing the GOST-R Certification Mark Sun StorageTek PCI Express Enterprise 4 Gb FC HBA Emulex Installation Guide • December 2005...
Safety Agency Compliance Statements Read this section before beginning any procedure. The following text provides safety precautions to follow when installing a Sun Microsystems product. Safety Precautions For your protection, observe the following safety precautions when setting up your equipment: Follow all cautions and instructions marked on the ■...
Do not connect the power cord when the power supply has been removed from the system chassis. Sun StorageTek Enterprise PCI Express 4 Gb FC Host Bus Adapters Emulex Installation Guide • December 2005 The following caution applies only to devices with multiple power cords: Caution –...
Rack System Warning The following warnings apply to Racks and Rack Mounted systems. Caution – For safety, equipment should always be loaded from the bottom up. That is, install the equipment that will be mounted in the lowest part of the rack first, then the next higher systems, etc.
Page 36
Conformité SELV Le niveau de sécurité des connexions E/S est conforme aux normes SELV. Sun StorageTek Enterprise PCI Express 4 Gb FC Host Bus Adapters Emulex Installation Guide • December 2005 Connexion du cordon d’alimentation Les produits Sun sont conçus pour fonctionner avec des systèmes...
Page 37
Mise en garde relative aux batteries Les batteries risquent d’exploser en cas de manipulation maladroite ou de remplacement incorrect. Pour les systèmes dont les batteries sont remplaçables, effectuez les remplacements uniquement selon le modèle du fabricant ou un modèle équivalent recommandé...
Page 38
Einhaltung sicherheitsbehördlicher Vorschriften Lesen Sie vor dem Ausführen von Arbeiten diesen Abschnitt. Im folgenden Text werden Sicherheitsvor- kehrungen beschrieben, die Sie bei der Installation eines Sun Microsystems-Produkts beachten müssen. Sicherheitsvorkehrungen Treffen Sie zu Ihrem eigenen Schutz bei der Installation des Geräts die folgenden Sicherheitsvorkehrungen: Beachten Sie alle auf den Geräten angebrachten Warnhinweise und Anweisungen.
Anschluss des Netzkabels Sun-Geräte sind für Stromversorgungssysteme mit einem geerdeten neutralen Leiter (geerdeter Rückleiter bei gleichstrombetriebenen Geräten) ausgelegt. Um die Gefahr von Stromschlägen zu vermeiden, schließen Sie das Gerät niemals an andere Stromversor- gungssysteme an. Wenden Sie sich an den zuständigen Gebäudeverwalter oder an einen qualifizierten Elektriker, wenn Sie nicht sicher wissen, an welche Art von Stromversor-...
Page 40
Verwenden Sie beim Einbau den Kippschutz am Rack, um ein Umkippen zu vermeiden. Um extreme Betriebstemperaturen im Rack zu vermeiden, stellen Sie sicher, dass die Maximaltemperatur die Nennleistung der Umgebungstemperatur für das Produkt nicht überschreitet Um extreme Betriebstemperaturen durch verringerte Luftzirkulation zu vermei- den, sollte die für den sicheren Betrieb des Geräts erforderliche Luftzirkulation eingesetzt werden.
Apagado – Espera – Colocación de un producto Sun No obstruya ni tape las rejillas del producto Sun. Nunca coloque un producto Sun cerca de radiadores ni fuentes de calor. Si no sigue estas indicaciones, el producto Sun podría sobrecalentarse y la fiabilidad de su funcionamiento se vería afectada.
Page 42
la utilización de láser Los productos Sun que utilizan tecnología láser cumplen los requisitos establecidos para los productos láser de clase 1. Class 1 Laser Product Luokan 1 Laserlaite Klasse 1 Laser Apparat Laser Klasse 1...
Page 43
Dispositivos de CD y DVD La siguiente medida se aplica a los dispositivos de CD y DVD, así como a otros dispositivos ópticos: La utilización de controles, ajustes o procedimientos distintos a los aquí especificados puede dar lugar a niveles de radiación peligrosos.
Need help?
Do you have a question about the StorageTek 4 Gb FC Host Bus and is the answer not in the manual?
Questions and answers