Flush Wall Installation
FINISHED WALL
3! OF NON-COMBUSTIBLE MATERIAL
FRONT TRIM OR NON-
COMBUSTIBLE MA TERIAL
(INSTALLA TION IS OPTIONAL)
Figure 12
Combustible Surround Installation
FINISHED WALL
2 X 4
HEADER
3! OF NON-COMBUSTIBLE MATERIAL
STAND OFF
Figure 13
Page 12
JOINT BETWEEN FINISHED
WALL AND UNIT SEALED
WITH 300° F, 149° C SEALANT
MATERIAL (SEALANT IS OPTIONAL)
MANTELSHELF
COMBUSTIBLE SURROUND
FRONT TRIM OR NON-COMBUSTIBLE
MATERIAL (INSTALLATION IS OPTIONAL)
JOINT BETWEEN FINISHED WALL AND
UNIT SEALED WITH 300° F 149
° C
SEALANT
MATERIAL (SEALANT IS OPTIONAL)
Attention: Cold climate installation recommendation:
When installing this unit against a non-insulated
exterior wall, it is mandatory that the outer walls be
insulated to conform to applicable insulation codes.
Vent Runs (Figures 14, 15, 16, 17 and 18)
In planning the installation for the fireplace, it is necessary to
install certain components before the appliance is completely
positioned and installed. These include the direct vent system,
gas piping for the appliance and the electrical wiring. (If the fan
option is used.)
The appliance can be mounted on any of the following surfaces:
1. A flat, hard combustible (burnable) surface.
2. A raised wooden platform.
3. Four (4) corner supports. (Example: Four (4) concrete masonry
blocks.) These supports must be positioned so they contact all
four (4) perimeter edges on the bottom of the unit.
VERTICAL, 90° ELBOW WITH HORIZONTAL
TERMINATION
DVP42, 48
49 ½"(126 mm)
TO BOTTOM
OF UNIT
Figure 14
VENT CAP/
THIMBLE
/
THIMBLE