HOW TO USE THE REMOTE CONTROL UNIT
Access without code
1) HOW TO ENABLE THE CONTROLLER TO RECEIVE THE REMOTE
CONTROL UNIT TRANSMISSION
press the 'ENABLE' button to operate the remote control unit;
the controller's led indicator above the digits flashes and the first
parameter - '/C' - is immediately displayed. If the display shows a
code different from /C, it is necessary to introduce the access
code (see point 5 below).
2) MODIFYING THE MAIN PARAMETERS
press either the + or - key relative to the parameter you want to
modify. The display will show the code of the selected
parameter (see the codes of the parameters listed in the
Instruction Sheet of the instrument). Press the button again to
display the value associated to the selected parameter and
press + to increase it;
press - to decrease it.
The section including directly accessible buttons also comprises 3 buttons
that activate/deactivate the function they represent:
DEFROSTING SECTION:
START
activates/deactivates a manual defrosting cycle;
evap.tmp displays the temperature value measured by the evaporator
probe (if present) or the value measured by the second probe
(Thermometer EC2-000).
Important: This function is always active. Consequently the
temperature measured by the second probe will be always
displayed without having to press the 'START' button or
select the access code (see point 5 below).
CONTINUOUS CYCLE SECTION:
C.cycle. activates a continuous cycle;
see point 4 below to exit the programming procedure.
3) HOW TO MODIFY THE PARAMETERS NOT DIRECTLY INDICATED
BY A SPECIFIC BUTTON
The other parameters - not directly associated to a specific button on the
remote control unit - can be easily modified as follows:
perform the same operations described in point 1 above until the
first parameter '/C' appears on the display;
3.1
press either
or
want to modify;
press SEL to display the value of the selected parameter;
press either
or
press SEL to confirm temporarily the new value and display again
the code of the parameter;
to modify another parameter repeat the operations described
above starting from point 3.1;
see point 4 below to exit the programming procedure.
4) HOW TO EXIT THE PROGRAMMING PROCEDURE
press PRG to exit and memorize all modifications;
press ESC to exit without memorizing the previous
modifications;
do not press any button for at least 60 seconds (TIME OUT).
In this way the previous modifications will be cancelled.
Emerson Electric GmbH & Co.OHG is not to be held responsible for erroneous
literature regarding capacities, dimensions, applications, etc. stated herein.
Products, specifications and data in this literature are subject to change without
notice. The information given herein is based on technical data and tests which
ALCO CONTROLS believes to be reliable and which are in compliance with
technical knowledge of today. It is intended only for use by persons having the
Emerson Electric GmbH & Co OHG - Postfach 1251 - Heerstraße 111 - D-71332 Waiblingen - Germany - Phone .49-(0)7151-509-0 - Fax .49-(0)7151-509-200
EC2-IR__65046__R01.doc Rev.: 01
Infrared Remote Control for EC2
until the display shows the parameter you
to increase/decrease its value;
www.eCopeland.com/alcoliterature.cfm
Replacement for Rev.:00
Operating Instructions
Access with code
5) HOW TO ENABLE THE CONTROLLER TO RECEIVE THE REMOTE
CONTROL UNIT TRANSMISSION
press 'ENABLE' to operate the remote control unit;
all the controllers exposed to the beam of the remote control unit
will display their own access code;
select the access code of the controller whose parameter you
intend to modify using the numeric section on the remote control
unit. Select the code correctly (if the code of the controller is 05,
press 0 and 5).
the controller's led indicator above the digits flashes and,
simultaneously, the code of the first parameter '/C' appears on the
display.
perform the same operations described in point
above.
HOW TO SELECT THE ACCESS CODE
SETTING THE ACCESS CODE
All EC2 controllers have no factory-set access codes. The User can
choose and set his own access codes by simply modifying the H3
parameter as follows:
press 'ENABLE' to operate the remote control unit;
the controller's led indicator above the digits flashes and the first
parameter ('/C) appears immediately.
press
press SEL to display its value (default 00);
press
press SEL to confirm the new value and display again the H3
code;
press PRG to memorize the access code and exit the
procedure.
REMOVING THE CODE
repeat the operations described above and give the H3 parameter
the value 00 (H3=00). In this way you can program your
controller/s without selecting the access code.
WHAT TO DO IF THE REMOTE CONTROL DOESN'T WORK
check that the remote control is equipped with batteries aligned
correctly;
replace spent or weak batteries;
check that there are no obstacles between controller and
transmitter;
periodically clean the transmitter and the controller with a soft cloth;
remember that the remote control's usable range is within 3 meters
away from the controller.
in case parameters are accessible but the user is not allowed to
change values, verify "H2" parameter (refer to the USER manual)
MODELS
There are several versions available, in different languages:
Language
English
German
French
Spanish
Italian
appropriate technical knowledge and skills, at their own discretion and risk. Since
conditions of use are outside of ALCO'S control we cannot assume any liability for
results obtained or damages occurred due to improper application.
This document replaces all former versions.
to display the H3 parameter;
to select the desired value (from 01 to 199);
Type
Order Nr.
EC2- IRE
804 345
EC2- IRD
804 346
EC2- IRF
804 347
EC2- IRS
804 348
EC2- IRI
804 349