Download Print this page

Lincoln Electric US-M1800-LS Datasheet

Covered electrode

Advertisement

Quick Links

M A T E R I A L S A F E T Y D A T A S H E E T
Conforms to Hazard Communication Standard 29CFR 1910.1200 Rev. October 1988
Manufacturer/
The Lincoln Electric Company
Supplier:
22801 St. Clair Avenue
Cleveland, OH 44117-1199
(216) 481-8100
I M P O R T A N T !
This section covers the materials from which this product is manufactured. The fumes and gases produced during welding with the normal
use of this product are covered by Section V; see it for industrial hygiene information.
CAS Number shown is representative for the ingredients listed. All ingredients listed may not be present in all sizes.
(1)
The term "hazardous" in "Hazardous Materials" should be interpreted as a term required and defined in the Hazards Communication
Standard and does not necessarily imply the existence of any hazard. All materials are listed on the TSCA inventory.
Ingredients:
Chromium and chromium alloys or compounds (as Cr)*****
Limestone and/or calcium carbonate
Molybdenum alloys (as Mo)
Iron
Silicates and other binders
Fluorides (as F)
Manganese and/or manganese alloys and compounds (as Mn)*****
Niobium alloys (as Nb)
Tungsten alloys and compounds (as W)
Mineral silicates
Silicon and/or silicon alloys and compounds (as Si)
Titanium dioxides (as Ti)*****
Titanium and/or titanium alloys (as Ti)
Aluminum and/or aluminum alloys (as Al)*****
Nickel core wire*****
Supplemental Information:
is 10 milligrams per cubic meter. PEL value for iron oxide is 10 milligrams per
cubic meter. TLV value for iron oxide is 5 milligrams per cubic meter.
(**)
As respirable dust.
(*****)
Subject to the reporting requirements of Sections 311, 312, and 313 of
the Emergency Planning and Community Right-to-Know Act of 1986
and of 40CFR 370 and 372.
Non Flammable; Welding arc and sparks can ignite combustibles and flammable products. See Z49.1 referenced in Section VI.
Product is inert, no special handling or spill procedures required. Not regulated by DOT.
Rev 11/06b
Date:
Trade Name:
Sizes:
Supersedes:
For Welding Consumables and Related Products
SECTION I - IDENTIFICATION
SECTION II - HAZARDOUS MATERIAL (1)
(*) Not listed. Nuisance value maximum
SECTION III - HAZARD DATA
11/5/06
MSDS No.:
Blue Max Nyloid 2
All
2/1/04
Product Type:
Covered Electrode
AWS ENiCrMo-6
Classification:
CAS No.
Wt.%
7440-47-3
1317-65-3
7439-98-7
7439-89-6
1344-09-8
7789-75-5
7439-96-5
7440-03-1
7440-33-7
1332-58-7
7440-21-3
13463-67-7
< 0.5
12719-90-3
< 0.5
7429-90-5
< 0.5
7440-02-0
(b) The OSHA PEL for chromium (VI) is 5 micrograms
(0.005 milligrams) per cubic meter. The TLV for water
soluble chromium (VI) is 0.05 milligrams per cubic meter
and the TLV for insoluble chromium (VI) is 0.01
milligrams per cubic meter.
(c) Values are for manganese fume. STEL (Short Term
Exposure Limit) is 3.0 milligrams per cubic meter.
Values are those proposed by OSHA in 1989. Present
PEL is 5.0 milligrams per cubic meter (ceiling value).
(CONTINUED ON SIDE TWO)
US-M1800-LS
TLV
PEL
3
mg/m
mg/m
10
0.5(b)
1.0(b)
10
10
15
5
10
10
< 5
10*
10*
< 5
10*
10*
< 5
2.5
2.5
< 5
0.2
1.0(c)
< 5
10*
10*
1
5
5
0.5
5**
5**
0.5
10*
10*
10
15
10*
10*
10
15
55
1.5
1
3

Advertisement

loading

Summary of Contents for Lincoln Electric US-M1800-LS

  • Page 1 M A T E R I A L S A F E T Y D A T A S H E E T For Welding Consumables and Related Products Conforms to Hazard Communication Standard 29CFR 1910.1200 Rev. October 1988 SECTION I - IDENTIFICATION Manufacturer/ The Lincoln Electric Company Product Type: Covered Electrode Supplier: 22801 St. Clair Avenue...
  • Page 2 Blue Max Nyloid 2 Product: Date: 2/1/04 SECTION IV - HEALTH HAZARD DATA Threshold Limit Value: The ACGIH recommended general limit for Welding Fume NOS - (Not Otherwise Specified) is 5 mg/m ACGIH-1999 preface states that the TLV-TWA should be used as guides in the control of health hazards and should not be used as fine lines between safe and dangerous concentrations.

This manual is also suitable for:

Blue max nyloid 2