Current 2600 Instructions Manual

Prime drop-in chiller

Advertisement

Quick Links

Prime Drop-In Chiller
Instructions for Drop-In Coil Model
#2600,2601,2602,2603
Chiller Installation ....... Page 3
Warranty ....... Page 8
EMAIL:INFO@CURRENT-USA.COM
WWW.CURRENT-USA.COM
05-2005-JEE

Advertisement

loading

Summary of Contents for Current 2600

  • Page 1: Table Of Contents

    Prime Drop-In Chiller ™ Instructions for Drop-In Coil Model #2600,2601,2602,2603 Warning and Safety Instructions ..Page 2 Chiller Installation ..Page 3 Temperature Controller Installation ..Page 5 Programming Temperature Controller ..Page 6 Warranty ..Page 8 EMAIL:INFO@CURRENT-USA.COM WWW.CURRENT-USA.COM 05-2005-JEE...
  • Page 2: Warning And Safety Instructions

    MUST be connected to a ground fault circuit interrupter (GFCI) outlet at all times. Do not use extension cords. WARNING – To reduce the risk of electrocution, keep all connections dry and off the ground. Do not touch plug with wet hands. WWW.CURRENT-USA.COM...
  • Page 3: Chiller Installation

    12-22 gpm b) Make sure the pump will operate normally without any blockage. c) Make sure the chiller is plugged into a GFCI protected 110V power outlet. 8. Set the temperature controller to the desired temperature as instructed next. WWW.CURRENT-USA.COM...
  • Page 4 Chiller installation Ensure that both front and back of unit are at least 24" from any wall to allow proper air flow. Do not submerse coil below line Front Back Figure A WWW.CURRENT-USA.COM...
  • Page 5: Temperature Controller Installation

    3. Set the controller to the desired temperature and differential (see Programming the Controller.) A differential of 2 degrees (2° F/C) is recommended with many heat load situations to allow the chiller to completely cycle and prevent damage to the start-up components and compressor. WWW.CURRENT-USA.COM...
  • Page 6: Programming Temperature Controller

    C1. To operate a heater, thermostat must be set to H1. The factory setting is C1. Proceed to #5 for Dual Thermostats or press the SET key again to view current temperature and resume the normal operating mode.
  • Page 7: Error Messages

    This condition cannot be field repaired. been corrupted. Replace the control. Appears if calibration mode has Remove power to the control for at been entered. least five seconds. Reapply power. If the CL message still appeared, replace the control. WWW.CURRENT-USA.COM...
  • Page 8: Warranty

    If you discover a defect, Current USA, Inc. will, at it’s option, repair or replace the product at no charge to you, provided you return it during the warranty period. It is required that you present this warranty card and a copy of the bill of sale as proof of original purchase date, in the event the product needs repairs, within the warranty period.