Scanner Pinout Connections

The MS7220 scanner interfaces terminate to 10-pin modular jacks located
on the back of the unit. The serial # label indicates the interface enabled
when the scanner is shipped from the factory.
MS7220-12
OCIA
Pin
1
Ground
2
RS-232 Transmit Output
3
RS-232 Receive Input
4
RDATA
5
RDATA Return
6
Clock in
7
Clock out
Clock in Return/Clock out
8
Rtrn
9
+5VDC
10
Shield Ground
MS7220-12 Keyboard Wedge
Stand-Keyboard
Pin
1
Ground
2
RS-232 Transmit Output
3
RS-232 Receive Input
4
PC Data
5
PC Clock
6
KB Clock
7
PC +5V
8
KB Data
9
+5VDC
10
Shield Ground
Continued next page
40
C
T
ABLE
ERMINATIONS
Function
or
Function
MS7220-12
RS-232 or Light Pen
Pin
Function
1
Ground
2
RS-232 Transmit Output
3
RS-232 Receive Input
4
RTS Output
5
CTS Input
6
DTR Input/LTPN Source
7
Reserved
8
LTPN Data
9
+5VDC
10
Shield Ground