EEPROM Compulsory Initialization
All of EEPROM data are stored default setting
-method-
1. After setting C091=01, store '**FF' at EEPROM address 11d4(C092 setting).
2. Then press and hold the FUNC, UP, and DOWN key.
3. After that press RESET key and release.
4. Then INV starts compulsory initialization as it displays like below.
Now
5. EEPROM compulsory initialization completes.
6. Set Voltage-class (C197),and set C195,b085(both must be the same.)
7. Set INV kW Code (C196) the wrong value once intentionally
and store, then set the right value. After that start initialization with b084
-C081,C082-
O-L adjustment at factory(not C81, not C82)
JPN version is 1 byte definition
Core:up to 3388(or before)
IO:up to 3433(or before)
EU/USA version is 2 byte definition from the beginning.
Core: 3440 or after
IO: 3441 or after
When initialization of b084 or copying C081 and C082 are set different value, so need to set
again.