The modifier character is the sum of the applicable option values based on
Code Type
Option Value
Code 39
Example: A Full ASCII bar code with check character W, A+I+MI+DW, is transmitted as ]A7AimId where 7 = (3+4).
Trioptic Code 39
Example: A Trioptic bar code 412356 is transmitted as ]X0412356
Code 128
Example: A Code (EAN) 128 bar code with Function 1 character in the first position, FNC1 Aim Id is transmitted as
]C1AimId
I 2 of 5
Example: An I 2 of 5 bar code without check digit, 4123, is transmitted as ]I04123
Codabar
Example: A standard Codabar bar code, 4123, is transmitted as ]F04123
Code 93
Example: A Code 93 bar code 012345678905 is transmitted as ]G0012345678905
D 2 of 5
Example: A D 2 of 5 bar code 4123, is transmitted as ]S04123
Table B-3. Modifier Characters
0
No Check character.
1
Reader has checked one check character.
3
Reader has checked and stripped check character.
4
Reader has performed Full ASCII character conversion.
5
Reader has performed Full ASCII character conversion and checked one check character.
7
Reader has performed Full ASCII character conversion and checked and stripped check character.
0
No option specified at this time. Always transmit 0.
0
Standard data packet, No Function code 1 in first symbol position.
1
Function code 1 in first symbol character position.
2
Function code 1 in second symbol character position.
0
No check digit processing.
1
Reader has validated check digit.
3
Reader has validated and stripped check digit.
0
Standard Codabar
1
ABC Codabar
0
No options specified at this time. Always transmit 0.
0
No options specified at this time. Always transmit 0.
Table
B-3.
Option
Programming Reference B-5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents