Instruction Manual HI 9810 Portable pH/EC/TDS Meter This Instrument is in h t t p : / / w w w . h a n n a i n s t . c o m Compliance with the CE Directives...
Dear Customer, PRELIMINARY EXAMINATION PRELIMINARY EXAMINATION PRELIMINARY EXAMINATION PRELIMINARY EXAMINATION PRELIMINARY EXAMINATION Thank you for choosing a Hanna product. Please read this instruction manual carefully before using the meter. Remove the instrument from the packing material and examine it This manual will provide you with the necessary information for a carefully to make sure that no damage has occurred during shipment.
F U N C T I O N A L D E S C R I P T I O N F U N C T I O N A L D E S C R I P T I O N F U N C T I O N A L D E S C R I P T I O N F U N C T I O N A L D E S C R I P T I O N F U N C T I O N A L D E S C R I P T I O N...
Page 4
TAKING EC/TDS MEASUREMENTS OPERATIONAL GUIDE OPERATIONAL GUIDE OPERATIONAL GUIDE OPERATIONAL GUIDE OPERATIONAL GUIDE • Immerse the tip of the electrode (4cm/1½") into the sample to be tested. If possible, use plastic beakers INITIAL PREPARATION or containers to minimize any EMC interference. Each meter is supplied complete with a 9V battery.
Page 5
p p p p p H CALIBRATION H CALIBRATION H CALIBRATION H CALIBRATION EC/TDS EC/TDS EC/TDS CALIBRATION CALIBRATION CALIBRATION CALIBRATION H CALIBRATION EC/TDS EC/TDS CALIBRATION For greatest accuracy, frequent calibration of the instrument is recom- Accessories needed: mended. The instrument should be recalibrated for pH: •...
p p p p p H VALUES AT VARIOUS H VALUES AT VARIOUS H VALUES AT VARIOUS H VALUES AT VARIOUS H VALUES AT VARIOUS TEMPERATURE COMPENSATION TEMPERATURE COMPENSATION TEMPERATURE COMPENSATION TEMPERATURE COMPENSATION TEMPERATURE COMPENSATION TEMPERATURES TEMPERATURES TEMPERATURES TEMPERATURES TEMPERATURES The conductivity of an aqueous solution is the measure of its ability to carry an electrical current by means of ionic motion.
CLEANING PROCEDURE ELECTRODE CONDITIONING ELECTRODE CONDITIONING ELECTRODE CONDITIONING ELECTRODE CONDITIONING ELECTRODE CONDITIONING Soak in Hanna HI 7061 General Cleaning Solu- General AND MAINTENANCE AND MAINTENANCE AND MAINTENANCE AND MAINTENANCE AND MAINTENANCE tion for approximately ½ hour. Removal of films, dirt or deposits on the membrane/junction: Soak in Hanna HI 7073 Protein Cleaning Solu- Protein tion for 15 minutes.
ELECTRODE STORAGE SOLUTIONS A C C E S S O R I E S A C C E S S O R I E S A C C E S S O R I E S A C C E S S O R I E S A C C E S S O R I E S HI 70300M Storage Solution, 230 mL HI 70300L...
BATTERY REPLACEMENT BATTERY REPLACEMENT BATTERY REPLACEMENT BATTERY REPLACEMENT BATTERY REPLACEMENT OTHER PRODUCTS FROM HANNA OTHER PRODUCTS FROM HANNA OTHER PRODUCTS FROM HANNA OTHER PRODUCTS FROM HANNA OTHER PRODUCTS FROM HANNA • CALIBRATION AND MAINTENANCE SOLUTIONS All meters are powered by a 9V battery that is located on the rear of the instrument.
If the repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization number from the Customer Service depart- ment and then send it with shipping costs prepaid.
Page 11
HANNA LITERATURE HANNA LITERATURE HANNA LITERATURE HANNA LITERATURE HANNA LITERATURE Hanna publishes a wide range of catalogs and handbooks for an equally wide range of applications. The reference literature currently covers areas such as: • Water Treatment • Process • Swimming Pools •...
Need help?
Do you have a question about the HI 9810 and is the answer not in the manual?
Questions and answers