3.7.2
Position of the stationary knife
1
2
3
Rule and control
The stationary knife 3, seen in the arrow direction, must be in contact
with the screw 1 (see the sketch).
Reground knives must be adjusted according to chapter 3.7.3 !
Caution: Danger of bodily injuries !
Turn off main switch.
Switch off the sewing machine before correcting the stationary knife.
Correction
–
Turn back the cutting pressure screws 2.
–
Loosen the screw 1 from below.
–
Push the knife 3 in the arrow direction against the screw 1.
–
Tighten the screw 1 slightly from above.
–
Adjust the cutting pressure (see chapter 3.7.6).
–
Tighten the screw 1 from below.
1
1
2
3
55