* Permissible limits of the voltage range at which the unit will operate satisfactorily
If wire is applied at ambient greater than 30° C (86° F), consult table 310 ---16 of the NEC (ANSI/NFPA 70). The ampacity of non ---metallic---sheathed
{
cable (NM), trade name ROMEX, shall be that of 60° C (140° F) conditions, per the NEC (ANSI/NFPA 70) Article 336 ---26. If other than uncoated
(no ---plated), 60 or 75° C (140° F or 167° F) insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used,
consul applicable tables of the NEC (ANSI/NFPA 70).
Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%.
}
** Time ---Delay fuse.
FLA
--- Full Load Amps
LRA
--- Locked Rotor Amps
MCA --- Minimum Circuit Amps
RLA
--- Rated Load Amps
NOTE: Control circuit is 24 ---V on all units and requires external power source. Copper wire must be used from service disconnect to unit.
All motors/compressors contain internal overload protection.
A- -WEIGHTED SOUND LEVEL (dBA)
UNIT SIZE --- SE-
STANDARD
RIES
RATING
72--- low stage
24---30
72--- high stage
72--- low stage
36---30
73--- high stage
76--- low stage
48---30
75--- high stage
76--- low stage
60---30
74--- high stage
CHARGING SUBCOOLING (TXV- -TYPE EXPANSION DEVICE)
OPER
COMPR
VOLTS*
MIN
LRA
RLA
52.0
10.3
82.0
16.7
187
96.0
21.2
118.0
25.6
TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)