16 Mix:Flange Level 0-10

17 Mix:Tap1 R Level 0-10

18 Mix:Tap1 L Level 0-10

19 Mix:Tap2 Level 0-10

20 Mix:Tap3 Level 0-10

21 Mix:Tap4 R Level 0-10
22 Mix:Tap4 L Level 0-10
28 Algorithm definitions
Each of the 28 algorithm definitions holds a 22 byte program definition (28
* 22 = 616 bytes). The 1st entry is the latest parameter settings for
algorithm 0, the 2nd entry is the latest parameter settings for algorithm 1,
etc. See Program Definitions for the structure of each of the 28 algorithms.
The DSP256 XL uses this table while changing a program's algorithm.
Program number (0-255)
Program number + 1 is the program that is running in the DSP256 XL.
Midi receive channel (0 - 17)
0 Receive MIDI Disabled

1-16 Receive MIDI on Channel 1-16

17 Receive MIDI on All Channels
Global link table of parameters to continuous controllers (P2CC)
All parameters in the DSP256 XL are assigned a parameter number. This number
is used as an offset into the P2CC table. The value of an entry in the P2CC
may be 0 through 129. 0 - 127 correspond to continuous controllers 0 - 127.
128 is Channel Pressure and 129 is NotLinked. The following table lists the

Hide quick links: