After all servicing:
− Check to see that all safety
devices are operational.
− Make sure that no tools or other
parts remain on or in the device.
Compressor does not run:
No mains voltage.
− Check cables, plug, outlet and
mains fuse.
Mains voltage too low.
− Use only extension cables with
sufficient lead cross section (see
"Technical Specifications"). Avoid
using extension cable with cold
device.
Compressor
was
unplugging.
− Switch compressor OFF at the
On/Off switch, then ON again.
Motor has overheated, caused by
insufficient cooling (cooling fins
covered).

9. Technical Specifications

Suction capacity
Free air delivery (volume flow rate)
Filling rate
Max. working pressure
Pressure vessel volume
Pump model
No. of cylinders
Motor speed
Motor capacity
Supply voltage (50 Hz)
Rated current
Fuse protection min.
Degree of protection
Maximum overall length when using extension cables with:
2
– 3 x 1.0 mm
lead cross-section
2
– 3 x 1.5 mm
lead cross-section
2
– 3 x 2.5 mm
lead cross-section
Dimensions: length x width x height
Weight
Sound pressure level at 1 m max.
10
− Remove cause for overheating
and allow to cool down for
approx. 10 minutes, then start
again.
Compressor runs but does not build
up sufficient pressure.
Condensate drain of pressure ves-
sel leaky.
− Check gasket of drain screw(s);
replace if necessary.
− Tighten drain screw(s) fingertight.
Check valve leaky.
− Have check valve serviced by
qualified service centre.
Air tool is not supplied with sufficient
pressure.
stopped
by
Pressure regulator not opened wide
enough.
− Open pressure regulator more.
Hose connection between compres-
sor and air tool leaky.
− Check air hoses, replace defec-
tive parts if necessary.
7. Repairs
A
Danger!
Repairs to power tools must be
carried out by qualified electricians
only!
Electric tools in need of repair can be
send to the service centre in your coun-
try. See spare parts list for address.
Please attach a description of the fault to
the power tool.

8. Environmental Protection

The device's packaging can be 100 %
recycled.
Worn out devices and accessories con-
tain considerable amounts of valuable
raw and plastic materials, which can be
recycled.
These instructions are printed on chlo-
rine-free bleached paper.
l/min
235
l/min
110
l/min
120
bar
8
l
4
F 245
1
-1
min
2850
kW
1.5
V
230
A
6.8
A
10 (time-lag)
IP 20
m
10
m
25
m
25
mm
600 x 310 x 405
kg
18
dB (A)
87 ± 3