Example Of Power Connections - Citizen BD2-1220 User Manual

Control board for lt-122x/132x
Hide thumbs Also See for BD2-1220:
Table of Contents

Advertisement

3.1.2 Example of Power Connections

* For the serial and parallel interface connections, see the sections dedicated to the respective
interface.
CPU
CAUTION:
(1) The ERROR and PEOUT LED lights have a current limiting resistor of 330
An LED with forward voltage drop under 2 V should thus be used for these lights. A driving current exceeding 10
mA could damage the control board electronics.
(2) The logic power supply (Vdd and GND) may have supply and return connections only to a single pin each.
However, the driver power supply (Vp and P-GND) must be connected to all the available pins in order to secure
the specified drive current capacity.
(3) As shown above, the LF-SW input connection is a circuit that uses a ceramic capacitor to prevent chattering. You
can adjust the switch if chattering is severe.
(4) The RESET input is pulled up to Vdd with an on-board 3.3K
(5) The serial interface uses RS-232C driver and receiver. Be sure to use RS-232C compatible signal levels for this
interface.
(6) Unused terminals should be insulated to keep exposed cable leads from them.
CN1
1, 2
3, 4
5 ~
10
11 ~
Vdd
16
10K
17
1000pF
330
18
330
19
Control Board
Vdd
+5V
GND
GND
Vp
+24V
+24V
P-GND
GND
LF SW
SW
ERROR LED
PEOUT LED
resistor. Leave it at NC if it will not be used.
6
BD2-1220/1221 User's Manual
AC100 ~
Regulated DC
power supply
Supply GND or
CN1-3 (4)
+5V
5V supply line or
CN1-1 (2)
each to limit driving current to 10 mA.
240V

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bd2-1221