22 electrolux
Extraction (Ducted)
The cooker hood is more effective when
installed in the extraction mode (ducted
to the outside).
Venting kits may be purchased through
EN
your retailer or DIY store, and must be
evacuated through an outside vent of
ø125 (5ins) or ø150mm (6ins).
The ducting used must be manufactured
from fi re retardent material conforming
to the relevant British Standard or DIN
4102-B1.
When the cooker hood is ducted to
the outside the charcoal fi lter must be
removed.
Fitting the Ducting
• Fit the ø150mm (6ins) ducting to the
spigot on top of the hood body as
illustrated.
• When using ø125mm (5ins) ducting fi t
item 9 and 10 on to the spigot on the
top of the hood body as illustrated.
• For the best performance use the
shortest possible run of ducting and
we recommend the use of rigid pipe in
preference to fl exible hose as this will
improve the fl ow of air while reducing
turbulence, which causes noise and a
loss of performance.
• If the room where the cooker hood
is to be used contains a fuel burning
appliance such as a central heating
boiler, then its fl ue must be be of the
room sealed or balanced fl ue type.
• If other types of fl ue or appliances are
fi tted ensure that there is an adequate
supply of air to the room.
• The cooker ducting when fi tted in
the extraction mode must never be
connected to central heating fl ues,
radiators or water heaters.