SERVICE (cont.)
SOLENOID VALVES
Disassembly:
1. Use of the basin wrench 01060.0000 is recom-
mended for disassembly of early style valves as
illustrated below.
2. Disconnect from power source and turn off the
water supply to the brewer.
3. Disconnect the water lines to and from the solenoid
valve.
4. Remove the two #8-32 screws securing the sole-
noid mounting bracket to the component bracket.
Remove solenoid bracket and solenoid valve as an
assembly.
5. Remove the two #10-32 screws and lock wash-
ers securing the solenoid valve to the solenoid
bracket.
6. Disassemble the valve according to the illustrations
that correspond to the particular valve you have.
7. On early style valves, leave the fittings installed
in the base to use as leverage. DO NOT CLAMP
THE BASE WITH LOCKING PLIERS AS THIS CAN
CAUSE DAMAGE!
8. Refer to Illustrated Parts Catalogs for replacement
solenoids and repair/rebuild kits.
120VAC - 247
240VAC - 757
FIG. 15-1 FIRST STYLE
FIG. 15-2 SECOND STYLE
120VAC - 1.18K
240VAC - 3.76K
FIG. 15-2 THIRD STYLE
Page 15
120VAC - 334
41711.1 052009