Technical Details

Dimensions - extractor version (in cm):
Height - Width - Depth 78,5/120 - 89,8 - 50,5
Maximum absorbed power:
Motor absorption:
Lighting:
Length of the cable:

Mounting accessories included

1 deflector
1 chimney support
1 reduction flange Ø 125-120 mm
1 remote control
1 charcoal filter (already fitted)
1 support bracket
8 wood-screws 5 x 45 mm (for wall mounting - 2 as spare parts)
8 wall plugs Ø 8 mm (for wall mounting - 2 as spare parts)
6 washers (2 for chimney supprot - 2 for lower fixing - 2 as spare
parts)
6 metal screws 3,5 x 9,5 (for chimney, deflector and connection flange
- 2 as spare parts)
2 metal screws 3,5 x 6,5 (for connection block and circuit board
support).
We reserve the right to change specifications and colours as a result
of our policy of continuing technological development.

Electrical connection

Safety warnings for the electrician

The electric outlet should be placed on the wall inside the chimney.
The hood has a power cable, 150 cm, with earth connection and the
rated voltage is 220 - 240 V.
Connect the hood to the mains supply via a double pole switch
which has 3 mm minimum separation between the contacts.
The switch must be accessible at all times.
The following is valid in the United Kingdom only:
- the wire which is coloured green and yellow must be connected to
the terminal which is marked with the letter E or by the earth symbol
(
), or coloured green or green and yellow;
- the wire which is coloured blue must be connected to the terminal
which is marked with the letter N or coloured black, -
- the wire which is coloured brown must be connected to the terminal
which is marked with the letter L or coloured red.
340 W
1 x 300 W
2 x 20W
120 cm
17