Diagnostic Error Code
015-196-XXX USB port test halt, error threshold exceeded
015-197-XXX USB port test warning
015-198-XXX USB port test aborted
015-199-XXX USB port test failed, cause unknown
018-000-XXX PCI Card Test Passed
018-0XX-XXX PCI Card Failure
018-195-XXX PCI Card Test aborted by user
018-196-XXX PCI Card test halt, error threshold exceeded
018-197-XXX PCI Card test warning
018-198-XXX PCI Card test aborted
018-199-XXX PCI Card test failed, cause unknown
70
ThinkCentre Hardware Maintenance Manual
FRU/Action
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility program" on page 57.
2. Re-run test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility program" on page 57.
2. Flash the system and re-test. See "Flash update
procedures" on page 217.
3. Go to "Undetermined problems" on page 82.
1. Go to "Undetermined problems" on page 82.
2. Flash the system and re-test. See "Flash update
procedures" on page 217.
3. Replace component under function test.
No action
1. Riser card, if installed.
2. System board
1. PCI card
2. Information only Restart the test, if necessary
1. Press F3 to review the log file
2. Restart the test to reset the log file
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility program" on page 57.
2. Re-run test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility program" on page 57.
2. Flash the system and re-test. See "Flash update
procedures" on page 217.
3. Go to "Undetermined problems" on page 82.
1. Go to "Undetermined problems" on page 82.
2. Flash the system and re-test. See "Flash update
procedures" on page 217.
3. Replace component under function test.