Bryant LEGACY 124A Product Data

Bryant LEGACY 124A Product Data

Legacy line 14 air conditioner with puron refrigerant 1-1/2 to 5 tons (sizes 018 to 060)

Advertisement

124A
LEGACYt LINE 14 AIR CONDITIONER
WITH PURONr REFRIGERANT
1- - 1/2 TO 5 TONS (SIZES 018 TO 060)
the environmentally sound refrigerant
Bryant Air Conditioners with Puron r refrigerant provide a
collection of features unmatched by any other family of
equipment. The 124A has been designed utilizing Bryant's Puron
refrigerant. The environmentally sound refrigerant allows you to
make a responsible decision in the protection of the earth's ozone
layer.
As an Energy Star r Partner, Bryant Heating & Cooling has
determined that this product meets the Energy Starr guidelines
for energy efficiency. Refer to the combination ratings in the
Product Data for system combinations that meet Energy Starr
guidelines.
NOTE: Ratings contained in this document are subject to
change at any time. Always refer to the AHRI directory
(www.ahridirectory.org) for the most up- -to- -date ratings
information.

PRODUCT DATA

TM
INDUSTRY LEADING
FEATURES / BENEFITS
Efficiency
S
14 SEER / 11.5 - - 12.0 EER
S
Microtube Technologyt refrigeration system
S
Indoor air quality accessories available
Sound
S
Sound level as low as 72 dBA
S
Compressor sound blanket
Comfort
System supports Thermidistatt or standard thermostat
S
controls
Reliability
S
Puronr refrigerant - - environmentally sound, won't
deplete the ozone layer and low lifetime service cost.
S
Front- -seating service valves
S
Scroll compressor
S
Internal pressure relief valve
S
Internal thermal overload
S
Low pressure switch
S
High pressure switch
S
Filter drier
S
Balanced refrigeration system for maximum reliability
Durability
DuraGuardt protection package:
S
Solid, Durable sheet metal construction
S
Steel louver coil guard
S
Baked- -on, complete outer coverage, powder paint
Color matched ceramic coated screws
S
Applications
S
Long- -line - - up to 250 feet (76.2 m) total equivalent
length, up to 200 feet (60.96 m) condenser above
evaporator, or up to 80 ft. (24.38 m) evaporator above
condenser (See Longline Guide for more information.)
S
Low ambient (down to - -20_F/- -28.9_C) with accessory
kit

Advertisement

Table of Contents
loading

Summary of Contents for Bryant LEGACY 124A

  • Page 1: Product Data

    Steel louver coil guard layer. As an Energy Star r Partner, Bryant Heating & Cooling has Baked- -on, complete outer coverage, powder paint determined that this product meets the Energy Starr guidelines Color matched ceramic coated screws for energy efficiency.
  • Page 2: Model Number Nomenclature

    MODEL NUMBER NOMENCLATURE Product Tier SEER Major Se- Voltage Variations Cooling Capacity Open Open Open Minor Family ries Series 1=AC 4=14 A=Puron 0=Not Legacy SEER 208 ---230 --- Standard Defined Original 1 or Defined Defined Series 208/230 ---1 ISO 9001:2000 the environmentally sound refrigerant REGISTERED This product has been designed and manufactured to...
  • Page 3: Physical Data

    PHYSICAL DATA UNIT SIZE --- SERIES 018---C 024---D 030---D 036---C 042---D 048---C 060---C Operating Weight lb (kg) 195 (88.4) 184 (83.5) 177 (80.3) 225 (102.1) 228 (103.4) 270 (122.5) 337 (152.9) Shipping Weight lb (kg) 223 (101.2) 223 (101.2) 218 (98.9) 259 (117.5) 267 (121.1) 303 (137.4)
  • Page 4 ACCESSORIES ORDER NUMBER DESCRIPTION 018---C 024---D 030---D 036---C 042---D 048---C 060---C KAACH1201AAA CRANKCASE HTR KAACH1401AAA CRANKCASE HTR KSACY0101AAA CYCLE PROTECTOR KAAFT0101AAA FREEZE THERMOSTAT KSAHS1701AAA HARD START (CAP / RELAY) KSALA0301410* LOW AMBIENT PSW HC32GE229 MOTOR FAN BALL BEARING HC38GE228 MOTOR FAN BALL BEARING HC40GE228 MOTOR FAN BALL BEARING KSALA0601AAA*...
  • Page 5 Required in long line applications. 9. Outdoor Air Temperature Sensor Suggested in all commercial applications. Designed for use with Bryant Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out.
  • Page 6 Accessory Description and Usage (Listed Alphabetically) (Continued) 10. Sound Hood 13. Time- -Delay Relay Wraparound sound reducing cover for the compressor. Reduces An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor the sound level by about 2 dBA.
  • Page 7: Electrical Data

    ELECTRICAL DATA OPER MIN WIRE UNIT FUSE** COMPR WIRE LENGTH LENGTH VOLTS* SIZE{ or CKT SIZE --- V/PH SIZE{ ft. (m)} ft. (m)} SERIES 60° C 75° C 60° C 75° C AMPS 018---C 48.0 11.7 67 (20.4) 64 (19.5) 024---D 58.3 13.5...
  • Page 10 Wall...
  • Page 11 COMBINATION RATINGS ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER Phase 3047865 124ANA018---C *CAP**2414A**+TDR 18000 11.50 14.00 3047866 124ANA018---C CAP**1814A** 313*AV024045 18000 12.75 15.25 3047873 124ANA018---C CAP**1814A** 315(A,J)AV036070 17600 12.50 15.00 3047872 124ANA018---C CAP**1814A**+TDR 17800 11.20 13.50 3047867 124ANA018---C CAP**2414A**...
  • Page 12: Combination Ratings Continued

    COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER Phase 3047956 124ANA024---D CNPH*3017A** 315(A,J)AV066135 23400 13.00 15.50 3047957 124ANA024---D CNPH*3017A** 315(A,J)AV066155 23400 13.20 16.00 3101995 124ANA024---D CNPH*3017A** 353AAV036040 23800 13.20 16.00 3101996 124ANA024---D CNPH*3017A** 353AAV036060 23800 13.20 16.00...
  • Page 13 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER Phase 3102025 124ANA030---D CAP**3617A** 353AAV036060 29200 13.00 15.50 3102026 124ANA030---D CAP**3617A** 353AAV036080 29200 13.00 15.50 3102027 124ANA030---D CAP**3617A** 353AAV048080 29200 13.00 15.50 3048016 124ANA030---D CAP**3617A** 355(A,C)AV042060 28800 12.50 15.00...
  • Page 14 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER Phase 3048061 124ANA030---D CSPH*3012A**+TDR 29000 11.70 14.00 3048007 124ANA030---D CSPH*3612A** 313*AV048070 29400 12.50 15.25 3048008 124ANA030---D CSPH*3612A** 313*AV048090 29400 13.00 15.50 3048080 124ANA030---D CSPH*3612A** 315(A,J)AV036070 29000 12.50 15.50 3048081...
  • Page 15 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER Phase 3048157 124ANA036---C CNPH*4221A** 355(A,C)AV042040 35200 13.00 15.00 3048156 124ANA036---C CNPH*4221A**+TDR 35200 12.00 14.00 3048105 124ANA036---C CNPV*3617A** 313*AV048070 35000 12.20 14.50 3048182 124ANA036---C CNPV*3617A** 315(A,J)AV036070 35000 12.50 14.50 3048146...
  • Page 16 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER Phase 3048223 124ANA042---D CAP**4817A** 355(A,C)AV042060 40000 12.20 14.50 3048222 124ANA042---D CAP**4817A**+TDR 40000 12.00 14.00 3048188 124ANA042---D CAP**4821A** 313*AV048090 40000 12.75 15.00 3048189 124ANA042---D CAP**4821A** 313*AV060110 40000 13.00 15.25 3048228...
  • Page 17 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER Phase 3048282 124ANA042---D CSPH*4212A** 315(A,J)AV048090 39500 12.50 15.00 3048283 124ANA042---D CSPH*4212A** 315(A,J)AV060110 39500 12.20 15.00 3048284 124ANA042---D CSPH*4212A** 315(A,J)AV066135 39500 12.50 15.00 3048285 124ANA042---D CSPH*4212A** 315(A,J)AV066155 39500 12.50 15.00...
  • Page 18 COMBINATION RATINGS CONTINUED ARI Ref. No. Model Number Indoor Model Furnace Model Capacity SEER Phase 3048328 124ANA048---C CNPH*6024A** 313*AV060135 48000 12.20 14.75 3048371 124ANA048---C CNPH*6024A** 315(A,J)AV048090 46500 12.00 14.50 3102113 124ANA048---C CNPH*6024A** 353AAV048080 47000 12.00 14.00 3102114 124ANA048---C CNPH*6024A** 353AAV060100 47000 12.20 14.50...
  • Page 19 TDR — Time---Delay Relay. In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are equipped with TDR.
  • Page 30 CONDENSER ONLY RATINGS* CONDENSER ENTERING AIR TEMPERATURES ° F (° C) ° F (° C) 55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51.67) 124ANA018--- C 16.80 15.70 14.70 13.80 12.80 11.80 10.80 9.70 66.70 76.10...
  • Page 31 CONDENSER ONLY RATINGS* CONTINUED CONDENSER ENTERING AIR TEMPERATURES ° F (° C) ° F (° C) 55 (12.78) 65 (18.33) 75 (23.89) 85 (29.44) 95 (35.0) 105 (40.56) 115 (46.11) 125 (51.67) 124ANA042--- D 36.60 34.70 32.80 30.80 28.70 26.60 24.30 21.90 67.50...
  • Page 32: Operating Characteristics

    Catalog No. PDS124A ---07 E 2009 Bryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 02/09 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Table of Contents