Installation; Installation Location; Your Refrigerator Needs Ventilation - AEG SANTO K 78800 Operating And Installation Instructions

Built-in refrigerator
Table of Contents

Advertisement

Installation

Installation Location

The appliance should be set up in a well ventilated, dry room.
Energy use and efficient performance of the appliance is affected by
the ambient temperature.
The appliance should therefore
– not be exposed to direct sunlight;
– not be installed next to radiators, boilers or in a very cold room e.g.
an outhouse;
– only be installed at a location whose ambient temperature
corresponds to the climate classification, for which the appliance is
designed.
The climate classification can be found on the rating plate, which is
located at the left on the inside of the appliance.
The following table shows which ambient temperature is correct for
each climate classification:
Climate classification
If the refrigeration appliance is installed next to another refrigerator
or freezer a clearance of 5 cm at the sides is required, in order to pre-
vent the formation of condensation on the outside of the appliance.

Your refrigerator needs ventilation

Integratable models (i-appliances)
The integrated door of the furniture cabi-
net largely seals the installation recess. i-
appliances must therefore be provided
with ventilation by having an opening in
the furniture plinth. The warmed air must
be able to be exhausted upwards through
the air shaft on the furniture back.
The ventilation cross-sections should be
at least 200 cm
SN
N
ST
T
.
2
for an ambient temperature of
+10 to +32 °C
+16 to +32 °C
+18 to +38 °C
+18 to +43 °C
2
min. 200 cm
50
min. 200 cm
2
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Santo k 78800 i

Table of Contents