Lenovo ThinkCentre A58 Hardware Maintenance Manual page 64

Hardware maintenance manual
Hide thumbs Also See for ThinkCentre A58:
Table of Contents

Advertisement

58
Hardware Maintenance Manual
Diagnostic error code
001-025-XXX
System Checksum Value error
001-026-XXX
System FLASH data error
001-027-XXX
System Configuration/Setup error
001-032-XXX
System Device Controller failure
001-034-XXX
System Device Buffer Allocation failure
001-035-XXX
System Device Reset condition detected
001-036-XXX
System Register error
001-038-XXX
System Extension failure
001-039-XXX
System DMI data structure error
001-040-XXX
System IRQ failure
001-041-XXX
System DMA failure
001-195-XXX
System Test aborted by user
001-196-XXX
System test halt, error threshold exceeded
001-197-XXX
System test warning
FRU/Action
1. Flash the system. See "Updating
(flashing) BIOS from a disc" on page
134
2. System board
1. Flash the system. See "Updating
(flashing) BIOS from a disc" on page
134
2. System board
1. Run Setup
2. Flash the system. See "Updating
(flashing) BIOS from a disc" on page 134
3. System board
System board
1. Reboot the system
2. Flash the system. See "Updating
(flashing) BIOS from a disc" on page 134
3. Run memory test
4. System board
System board
System board
1. Adapter card
2. System board
1. Flash the system. See "Updating
(flashing) BIOS from a disc" on page
134
2. System board
1. Power-off/on system and re-test
2. System board
1. Power-off/on system and re-test
2. System board
Information only
Re-start the test, if necessary
1. Press F3 to review the log file
2. Re-start the test to reset the log file
1. Make sure the component that is called
out is connected and/or enabled. See
Chapter 6, "Using the Setup Utility," on
page 51
2. Re-run test
3. Replace the component that is called out
in warning statement
4. Replace the component under test