2.7

Water quality

Water quality can have an impact on appliance performance and appliance longevity, and may not be covered by the
manufacturer's warranty.
For water analysis data call your local water department. If on a well system, have well water analyzed periodically. If
water quality is exceeding one or more of the values specified below, Bosch recommends installing a water condi-
tioner or softener.
Descri-
pH
TDS
ption
(Total
Dissolved
Solids)
Max.
pH
mg/l or
Levels
range
ppm
6.5-8.5
500
Table 2 Venting Specifications
6 720 607 909
GWH 345 ESR
1 GPM
2 GPM
3 GPM
water flow rate
GWH 450 ESR
1 GPM
2 GPM
3 GPM
water flow rate
Total
Aluminum
hardness
mg/l or
mg/l or
ppm
ppm
100 (6
0.2
grains)
4 GPM
5 GPM
4 GPM
5 GPM
Chlorides
Copper
Iron
mg/l or
mg/l or
mg/l or
ppm
ppm
ppm
250
1.0
0.3
Appliance details
6 GPM
6 GPM
Manganese
Zinc
mg/l or ppm
mg/l or
ppm
0.05
5.0