EUROLIGHT LD6230 Installation Instructions
Please make sure that each dimmer load is connected to a separate
channel. Never connect more than one output to just one common
neutral conductor.
ATTENTION: Due to electrocution danger, do not use your dimmer pack
if there are bare cables visible.
Connection Options for Flexible Usage
Output Connector (HARTING)
In the back of your LD6230 there is a cable bushing for connecting your
illuminants. Open the flap on the top of the LD6230 to get to the terminal clamps
used for this purpose. Here you have the option to retrofit a 16-pin HARTING
connector. To do that, you first have to remove the back-bearing cover sheet and
connect the HARTING connector to the terminal clamps.
PIN assignment/HARTING connector
PIN 1
Phase channel 1
E1 PIN 9
PIN 2
Phase channel 2
E2 PIN 10
PIN 3
Phase channel 3
E3 PIN 11
PIN 4
Phase channel 4
E4 PIN 12
PIN 5
Phase channel 5
E5 PIN 13
PIN 6
Phase channel 6
E6 PIN 14
PIN 7
free
PIN 15
PIN 8
free
PIN 16
Ground wires need to be fastened to their respective PE connectors
CEE Power Supply Connector
Also located in the back is a cable bushing for the mains supply. Here, you can
retrofit a 5-pin CEE 32 A mains connector by removing the back-bearing cover
sheet and connect the CEE high-voltage connector to the connecting terminal.
The following illustration shows how the connections are allocated:
L3
L2
N
L1
CEE connector pin allocation
Removable mains connector cables with mains interconnections
(pursuant IEC60320) must match the minimal load-carrying capacity
of the connector or must comply with the IEC60799 standard.
The interconnection and the cable must comply with prevalent
nominal values (maximal voltage and current).
During the installation, please adhere to the instructions provided by
the connector manufacturer.
Neutral channel 1
N
Neutral channel 2
N
Neutral channel 3
N
Neutral channel 4
N
Neutral channel 5
N
Neutral channel 6
N
free
free

Specifications

Channels
Number
Load per channel
Maximal load per channel
Frequency
Inputs
Power supply
Analog
Digital
Outputs
Digital
Load
System Fuses
Load securing per channel
Control section fuse
Power Supply
Voltage
USA/Canada
Europe/U.K./Australia
Maximum power consumption
Dimensions/Weight
Dimensions (H x W x D)
Weight
BEHRINGER continuously strives to assure the highest quality standards possible. Required modifications may
be implemented without prior notice. Technical data and the appearance of the unit may deviate from the above
values and/or illustrations.
6
0.2 A min./10 A max.
10 A using a 3-phase connector
50/60 Hz
3-phase connector, internal
terminal block/PG cable screw joint,
CEE connector (optional installation by
qualified personnel)
0 to +10 V via 8 pin DIN
DMX512 via XLR 5 pin
DMX512 via XLR 5 pin
Internal terminal block/PG cable screw
joint, HARTING
(optional installation by
®
qualified personnel)
10 A cable protection switch (type C)
2 x T 100 mA H/250 V 1 x T 160 mA
H/250 V for voltage range 220 - 230 V
(EU) 2 x T 160 mA H/250 V 1 x T 315 mA
H/250 V for voltage range 120 V (UL)
120 V~, 60 Hz
240 V~, 50 Hz
3 x 20 A
approx. 3 1/3 x 19 x 15 9/10"
approx. 84.3 x 482.6 x 403.8 mm
approx. 21.6 lbs / 9.80 kg