INSTALLATION INSTRUCTIONS EUROLIGHT LD6230
The lowest cable gauge between L1 and L3, incoming neutral
conductor (N) and protective earth (PE) is 4 mm
(AWG 12). For outgoing channels E1 to E6, use cables with
gauges corresponding to the loads used (2.5 mm
1.5 mm
(AWG 16)).
2
ˆ‡ƒˆ‡Ãh††r††€r‡Ãb6d
6 - 10
13 - 16
18 - 25
+
During the installation, please adhere to all
manufacturer instructions. Regardless from mains
supply voltage, the maximum output current of the
EUROLIGHT LD6230 is 10 A per dimmer circle.
+
Please make sure that each dimmer load is
connected to a separate channel. Never connect
more than one output to just one common neutral
conductor.
+
ATTENTION: Due to electrocution danger, do not use
your dimmer pack if there are bare cables visible.
CONNECTION OPTIONS FOR
FLEXIBLE USAGE
OUTPUT CONNECTOR (HARTING
In the back of your LD6230 there is a cable bushing for
connecting your illuminants. Open the flap on the top of the
LD6230 to get to the terminal clamps used for this purpose. Here
you have the option to retrofit a 16-pin HARTING
do that, you first have to remove the back-bearing cover sheet
and connect the HARTING
connector to the terminal clamps.
®
DIÃh††vt€r‡C6SUDIB Ãp‚rp‡‚…
PIN 1 Phase channel 1
E1 PIN 9 Neutral channel 1
PIN 2 Phase channel 2
E2 PIN 10 Neutral channel 2
PIN 3 Phase channel 3
E3 PIN 11 Neutral channel 3
PIN 4 Phase channel 4
E4 PIN 12 Neutral channel 4
PIN 5 Phase channel 5
E5 PIN 13 Neutral channel 5
PIN 6 Phase channel 6
E6 PIN 14 Neutral channel 6
PIN 7
free
-
PIN 8
free
-
Ground wires need to be fastened
to their respective PE connectors
CEE POWER SUPPLY CONNECTOR
Also located in the back is a cable bushing for the mains
supply. Here, you can retrofit a 5-pin CEE 32 A mains connector
by removing the back-bearing cover sheet and connect the CEE
high-voltage connector to the connecting terminal. The following
illustration shows how the connections are allocated:
4
All manuals and user guides at all-guides.com
2
(AWG 14) or
2
I‚€vhyÃp…‚††Ã
6XBÃ
VT6
†rp‡v‚Ãb€€ dÃ@V
1.5
16
2.5
14
4
12
)
®
connector. To
®
N
N
N
N
N
N
PIN 15
free
-
PIN 16
free
-
CEE connector pin allocation
+
Removable mains connector cables with mains
interconnections (pursuant IEC60320) must match
the minimal load-carrying capacity of the connector
or must comply with the IEC60799 standard. The
interconnection and the cable must comply with
prevalent nominal values (maximal voltage and
current).
+
During the installation, please adhere to the
instructions
provided
manufacturer.

SPECIFICATIONS

Channels
Number
6
Load per channel
0.2 A min./10 A max.
Maximal load per channel
10 A using a 3-phase connector
Frequency
50/60 Hz
Inputs
Power supply
3-phase connector, internal
terminal block/PG cable screw
joint, CEE connector (optional
installation by qualified
personnel)
Analog
0 to +10 V via 8 pin DIN
Digital
DMX512 via XLR 5 pin
Outputs
Digital
DMX512 via XLR 5 pin
Load
Internal terminal block/PG cable
screw joint, HARTING
installation by qualified
personnel)
System fuses
Load securing per channel
10 A cable protection switch
(type C)
Control section fuse
2 x T 100 mA H/250 V
1 x T 160 mA H/250 V
for voltage range 220 - 230 V (EU)
2 x T 160 mA H/250 V
1 x T 315 mA H/250 V
for voltage range 120 V (UL)
Power supply
Voltage
USA/Canada
120 V~, 60 Hz
Europe/U.K./Australia
240 V~, 50 Hz
Maximum power consumption 3 x 20 A
Dimensions/Weight
Dimensions (H x W x D)
approx. 3 1/3" (84.3 mm)
x 19" (482.6 mm)
x 15 9/10" (403.8 mm)
Weight
approx. 20.3 lbs. (9.2 kg)
BEHRINGER continuously strives to assure the highest quality
standards possible. Required modifications may be implemented without
prior notice. Technical data and the appearance of the unit may deviate
from the above values and/or illustrations.
by
the
connector
(optional
®

Advertisement

loading