Fault Finding

Preliminary Electrical Systems Check

START
Isolate appliance
and carry out:
A: Earth Continuity
check.
NO
YES
Has inlet fuse blown?
NO
Inlet wiring
faulty.
Rectify any
fault.
Isolate appliance and
carry out:
B: Insulation check.
Rectify any fault
including replacing
fuses as necessary.
22
Carry out:
C: Polarity check.
YES
PLUG (with cover removed)
Earth Wire
Green/Yellow
( )
Neutral Wire
Blue
Blue
Brown
Green
Yellow
Blue
Green
Brown
Yellow
Carry out:
D: Resistance to
Earth check.
Electricity supply
should now be
satisfactory.
SOCKET
(face view)
( )
E
N
L