Weekly Timer Operation - Fujitsu ASTG14LUCA Operating Manual

Room air conditioner compact wall mounted type
Table of Contents

Advertisement

WEEKLY TIMER OPERATION

Using in these cases of WEEKLY timer
The "OFF Timer" at which the operation will be stopped and the "ON Timer" at which the operation will be started can be combined,
and up to 4 reservations (program
Before creating the program, please adjust the week and time fi rst, and than send it to the air conditioner.
If the week and time are not adjusted, the program will not be operated at the set time.
Please refer to [Set the day of the week and current time] (page 5).
Example of how to set the timer 1
Monday to Friday
Program
Set the ON Timer with a temperature of 24°C for 7 am. Program
Program
Set the ON Timer with a temperature of 26°C for 5 pm. Program
Saturday
Program
~
No timer settings.
Sunday
If you set the OFF Timer for Program
Program
7:00 ON 24°C
Monday to
Wake up
Friday
Saturday
ON
Sunday
Example of how to set the timer 2
You can specify a given temperature in the ON setting in WEEKLY TIMER.
* You can set the temperature for Auto, Cool, and Dry within the range 18-30°C, for Heat the range is 10 or 16-30°C.
Even if you set 10, 16, or 17°C, if you run the product on Auto, Cool, or Dry it will run at 18°C.
During the heating season, even if you confi gure detailed settings with the temperature low when there is no one in the room and
high when there is someone there, the air conditioning will automatically switch over.
Program
7:00 ON 22°C
● Operations other than the temperature setting will be the same at the last time operation was stopped,
CAUTION!
● If you set the ON Timer and OFF Timer on the same and for the same time, the air conditioner will run
● If there is a power interrupting, such as due to a power outage during the WEEKLY timer setting or a
● You cannot use the ON/OFF together with the SLEEP timer.
15
) can be applied for one day, and 28 reservations for a week.
at 9:00, Program
Program
9:00 OFF
Program
ON
9:00 OFF
Program
9:00 ON 24°C
so Cooling → Heating → Cooling → Heating type of operations cannot be automatically set.
the ON Timer. If two ON Timers are set at the same time, the air-conditioning will run the program that
was set earlier.
circuit breaker cutting out, the internal timer of the air-conditioning will be incorrect. (see page 22 Auto
Restart) In such a case, the main timer lamp will notify you of this by fl ashing, so carry out matching of
the time and date. see page 5 Set the day of the week and current time)
If you want to run the product on WEEKLY TIMER after the time is up after using the ON/OFF Timer,
Program Timer, or SLEEP Timer within the WEEKLY TIMER, you need to set the WEEKLY TIMER again.
(see page 18)
Set the OFF timer for 9 am.
Set the OFF timer for 11 pm.
at 11:00, Program
at 17:00, and Program
Program
Leave for work
17:00 ON 26°C
Come back
home
No timer settings
Program
ON
11:00 OFF
Program
17:00 ON 26°C
at 23:00.
Program
Go to sleep
23:00 OFF
Program
ON
17:00 OFF
Program
23:00 ON 22°C
Program
23:00 OFF

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Astg18lucaAstg09lucaAotg09lucAotg14lucAotg18luc