Baxi Duo-tec Combi HE a Range Installation And Servicing Instructions page 48

Gas fired wall mounted condensing combination boiler
Hide thumbs Also See for Duo-tec Combi HE a Range:
Table of Contents

Advertisement

Sensing Pipe
Earth Lead
Gas Feed
Elbow
Fig. 91
Retaining Bracket
Boiler Chassis
Fig. 92
48
© Baxi Heating UK Ltd 2012
Venturi Inlet
Pipe
Gas Valve
Fig. 91a
Expansion Vessel
Lock Nut
14.0 Changing Components
14.23
IMPORTANT: After replacing the valve the CO
checked and adjusted as detailed in Section 15.0 Setting
the Gas Valve. Only change the valve if a suitable
calibrated combustion analyser is available, operated by a
competent person - see section 13.1.
1. Turn the gas cock off and undo the nut on the gas feed
elbow under the boiler.
2. Remove the screws securing the gas valve the boiler
bottom panel.
3. Pull off the power lead, earth lead and sensing pipe.
4. Undo the nut on the gas pipe at the gas/air inlet and the gas
valve. Remove the pipe, taking care not to lose the sealing
washers. Remove the valve.
5. Reassemble in reverse order, ensuring that all seals are in
place and the injector is fitted.
6. Reassemble in reverse order.
NOTE: To assist the boiler to light prior to final setting,
Throttle
Adjustment Screw
use a suitable hexagon key to wind out the Throttle
Adjustment Screw until it is flush with the valve body, then
turn the screw 4 full turns clockwise (Fig. 91a). If the boiler
will not light, or the correct CO
contact the 'heateam' technical helpline.
14.24
1. Drain the primary circuit and undo the nut on the vessel
connection pipe.
2. Undo and remove the locknut securing the vessel spigot to
the boiler air box.
3. Remove the bracket and vessel from the boiler.
4. Locate the retaining bracket on the upper flange of the
vessel and fit to the boiler.
5. Reassemble in reverse order.
Gas Valve (Fig. 91)
cannot be achieved
2
Expansion Vessel (Fig. 92)
must be
2

Hide quick links:

Advertisement

Table of Contents
loading