13
Remove debris and clean threshold & base.
Caulk end of threshold at wall per detail.
Match holes in magnetic jamb with holes in adjustment rail to
determine which mounting hole is for adjustment rail only.
Remove magnetic jambs and mount adjustment rail to wall
using three #8 x 2" pan head screws. To adjust magnetic jamb
for out of plumb wall conditions, insert adjustment screws
(three #8 x 1" pan head screws) as shown.
ADJUSTMENT RAIL
MOUNTING SCREW
MAGNETIC
JAMB
MATCH
HOLES
3 PLACES
ADJUSTMENT RAIL MOUNTING SCREW
#8 X 2" PAN HEAD SCREW
FOR "NS" MODELS,
ADJUSTMENT RAIL MOUNTING SCREW
#8 X 1-1/2" FLAT HEAD SCREW
15
Clean bottom rail.
Cut vinyl sweep the same length as drip rail. Insert sweep into
groove in drip rail.
Position drip rail on inside of doorframe 1/8" up from bottom
edge and set 1/2" from each outside edge. The drip rail must be
adjusted so that it angles down towards pivot side and does not
hit threshold or doorjambs when door is closed.
Mark the proper location and then remove backing from tape
and press drip rail in place. Apply a small dab of silicone into
the strike end of the drip rail before inserting plastic plug.
Note: Allow 24 hours for adhesive to cure before using shower.
DRIP CAP
ANGLE DOWN
ABOUT °1
ADJUSTMENT RAIL
SILICONE
CAULK
ADJUSTMENT
SCREW
ADJUSTMENT SCREW
#8 X 1" FLAT HEAD SCREW
FOR "NS" MODELS,
ADJUSTMENT SCREW
#8 X 5/8" FLAT HEAD SCREW
DRIP RAIL
VINYL
SWEEP
14
Place magnetic jamb over adjustment rail with magnetic
strip facing to outside of shower.
Close door and adjust magnetic jamb to allow 1/8" to 1/4"
clearance between magnetic jamb and door panel.
NOTE: If magnets repel each other, remove and reverse.
To adjust magnetic jamb for clearance or plumb, remove
magnetic jamb and reposition adjustment screws. Once
magnetic jamb is in desired position, secure with
mounting screws. The door may also be adjusted by
loosening the 1/4" nut, aligning strike side of door and
re-tightening door.
Install wall jamb cap by snapping in place at top of
adjustment rail. Trim with knife. For narrow strike
models, cut cap at mark with a utility knife.
MAGNETIC
JAMB
MOUNTING
SCREW
WALL JAMB CAP
16
Caulk where wall jamb meets wall for entire height of unit on
both inside and outside of shower.
Caulk where threshold meets base on outside of unit only.
Allow 24 hours for silicone to cure before using shower.
OUTSIDE VIEW
SILICONE
4
ADJUSTMENT
RAIL
MAGNETIC
JAMB
1/8"-1/4"
DOOR
ADJUSTMENT
SCREW
MAGNETIC
JAMB
MOUNTING
SCREW
INSIDE VIEW
SILICONE
7 1 0 0 0 7 - 1 0 0