Diagnostics
3) When COMP COOLING FAN does not operate
Start
Is COMP operating?
YES
Is it COMP
COOLING FAN ON
condition?
YES
Comp
Fan
DELAY
Is MICOM Pin
#28 "HIGH"(5V)?
YES
Is IC3 #15
"LOW"(0.7V)?
YES
Is RELAY(K74)normal?
YES
Is contact of
Connector CN71� PIN (BLUE)
normal?
YES
Check wire assembled
status/Chang MAIN PCB ASS'Y
NO
Operate Forced Operation
NO
Stand by for FAN ON condition
Confirm FAN operating condition
Ambient Temp Range
Higher than 71.6℉(22℃)
Between 62.6℉(17℃)~69.8℉(21℃)
Between 53.6℉(12℃)~69.8℉(16℃)
Between 44.6℉(7℃)~51.8℉(11℃)
Lower than 42.8℉(6℃)
NO
Check soldering /Change PCB
NO
Check soldering /Change PCB
NO
Check Relay / Change PCB
NO
Check contact of Connector
- Reference
• Load terminal Measure method.
Load Operation Status
Comp Fan operates immediately upon COMP ON
Comp Fan operates in 3 min after COMP ON
Comp Fan operates in 6 min after COMP ON
Comp Fan operates in 9 min after COMP ON
Comp Fan gets off regardless of COMP
CN71 again
62