Samsung RB215BSSB Service Manual page 39

Reversible door/auto ice-maker/fridge wire box
Hide thumbs Also See for RB215BSSB:
Table of Contents

Advertisement

Temp Control &Operation Functions
- Descriptions for each Self Diagnosis Lamp
No
Item
SENSOR HOUSING SLIP-OUT, CONTACT
1
F-SENSOR
(+50
SENSOR HOUSING SLIP-OUT, CONTACT
2
R-SENSOR
122
SENSOR HOUSING SLIP-OUT, CONTACT
F-DEFROST
3
SENSOR
122
SENSOR HOUSING SLIP-OUT, CONTACT
R-DEFROST
4
SENSOR
(+50
SENSOR HOUSING SLIP-OUT, CONTACT
I/M-SENSOR
5
122
SENSOR HOUSING SLIP-OUT, CONTACT
AMBIENT
6
SENSOR
122
F-ROOM HEATER (SENSOR HOUSING SLIP-
OUT, CONTACT DEFECT, WIRE CUT, WIRE
F-DEFROST
7
WHEN DEFROST DOES NOT FINISH EVEN
ERROR
SLIP-OUT, CONTACT DEFECT, WIRE CUT,
WIRE SHORT OR TEMP FUSE DEFECT)
R-DEFROST
8
WHEN DEFROST DOES NOT FINISH EVEN
ERROR
MORE THAN 3 TIMES OF ICE MAKER
I/M
KIT ICE EJECTION OR HORIZONTAL
FUNCTION
9
ERROR
Error
DEFECT,WIRE CUT, WIRE SHORT,
SENSOR TEMP MORE THAN 122
) OR LOWER THAN 122
DEFECT, WIRE CUT, WIRE SHORT,
SENSOR TEMP MORE THAN
(+50
)OR LOWER THAN 122
DEFECT, WIRE CUT, WIRE SHORT,
SENSOR TEMP MORE THAN
(+50
)OR LOWER THAN 122
DEFECT, WIRE CUT, WIRE SHORT,
SENSOR TEMP MORE THAN 122
)OR LOWER THAN 122
DEFECT, WIRE CUT, WIRE SHORT,
SENSOR TEMP MORE THAN
(+50
)OR LOWER THAN 122
DEFECT, WIRE CUT, WIRE SHORT,
SENSOR TEMP MORE THAN
(+50
)OR LOWER THAN 122
SHORT OR TEMP FUSE DEFECT)
AFTER A 70-MINUTE CONTINUOUS
HEATING, IT DISPLAYS THE ERROR.
R-ROOM HEATER (SENSOR HOUSING
AFTER A 80-MINUTE CONTINUOUS
HEATING, IT DISPLAYS THE ERROR.
LEVELING ERROR
VOLTAGE BETWEEN MAIN PCB CN30
2
3 SHALL BE WITHIN 4.5V~1.0V.
(-50
)
VOLTAGE BETWEEN MAIN PCB CN30
2
3 SHALL BE WITHIN 4.5V~1.0V.
(-50
)
VOLTAGE BETWEEN MAIN PCB CN30
2
3 SHALL BE WITHIN 4.5V~1.0V.
(-50
)
VOLTAGE BETWEEN MAIN PCB CN30
2
3 SHALL BE WITHIN 4.5V~1.0V.
(-50
)
VOLTAGE BETWEEN MAIN PCB CN30
2
3 SHALL BE WITHIN 4.5V~1.0V.
(-50
)
VOLTAGE BETWEEN MAIN PCB CN30
2
3 SHALL BE WITHIN 4.5V~1.0V.
(-50
)
AFTER SEPARATING THE MAIN PCB CN70 WIRE FROM
PCB, CHECK THE RESISTANCE BETWEEN BROWN
ORANGE. IT SHALL BE WITHIN ***OHM. (THE
RESISTANCE VARIES ACCORDING TO THE INPUT
POWER.) WHEN THE RESISTANCE IS 0 OHM,CHECK IF
THE HEATER IS SHORT AND WHEN IT IS
IF THE WIRE/TEMP FUSE IS OPEN
AFTER SEPARATING THE MAIN PCB CN70 WIRE FROM
PCB,CHECK THE RESISTANCE BETWEEN WHITE
ORANGE.IT SHALL BE WITHIN ***OHM. (THE
RESISTANCE VARIES ACCORDING TO THE INPUT
POWER.) WHEN THE RESISTANCE IS 0 OHM,CHECK IF
THE HEATER IS SHORT AND WHEN IT IS
IF THE WIRE/TEMP FUSE IS OPEN
ONLY APPLIED TO MODEL WITH
39
Self Diagnosis
OHM, CHECK
OHM,CHECK
ICE MAKER