Diagnosis - Panasonic CF-73ECLTXKM - Toughbook 73 - Pentium M 1.4 GHz Service Manual

Service manual
Table of Contents

Advertisement

9 Diagnosis

9.1 MAIN UNIT DIAGNOSIS(1/2)
Make sure that connecting cables, connectors and AC adapter are not loose or disconnected prior to testing.
No.
Symptom
1
No power is sent to the
unit. (When using AC)
No power is sent to the
unit. (When using the
Battery Pack)
2
Power cuts off during
operation.
9.2 MAIN UNIT DIAGNOSIS(2/2)
Make sure that connecting cables, connectors and AC adapter are not loose or disconnected prior to testing.
No.
Symptom
1
When a device is
selected for "Boot Up
Drive", the system boots
from a different device.
2
Date or Time cannot be
input.
Date and Time does not
change properly.
Date and Time are not
displayed.
3
Memory count is too large
or too small.
Troubleshooting
procedures
No.
Is 15V applied to pins 1-3 of
1-1
Q710? (Whichever one)?
Is 15V applied to pins 5-8 of
1-2
Q699?
Before setting the power
switch to ON, check voltage
1-3
on either side of SW1000 Is
Voltage 3.3V?
Is 8-12V applied to pins 1 of
1-5
Q681? (Whichever one)
Check soldered parts of
2-1
D666 ~ D668
D463 ~ D468.
Troubleshooting
procedures
No.
Are there system files in the
1-1
device selected?
Does the unit operate
1-2
normally after replacing the
problem device.
2-1
Replace the Main PCB.
3-1
Replace the Main PCB.
15
Source of
problem
Result
YES Go to No.1-3
NO
Go to No.1-2
YES Go to No.1-3
NO
Go to No.1-2
If voltage is 0V
during the power
switch is set to
YES
ON.
If not 0V
If voltage of C738
NO
is 3.3V
If lower than 3V
YES If voltage is 8-12V
NO
Main PCB
If they show
NO
soldered
completely
YES
Source of
problem
Result
YES Go to No.1-2
NO
Improper setting
Device for which
YES
the problem
occurred
NO
Main PCB
Main PCB
Main PCB
Component
Q699
SW1000
R705
R706
IC617
Q681
R589
R584, R585
R501 ~R506
IC605, IC606
IC616
Component
IC3
IC3
X2
RTC battery
IC4-11
IC2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents