Oregon Scientific BAR916HG User Manual

Oregon Scientific BAR916HG User Manual

Wireless weather station with world time clock
Hide thumbs Also See for BAR916HG:

Advertisement

Wireless Weather Station
with World Time Clock
Model: BAR916HG
USER MANUAL
CONTENTS
Introduction .............................................................. 3
Product Overview ..................................................... 4
Front View ............................................................. 4
Back View .............................................................. 5
Table Stand and Wall Mount.............................. 5
LCD Display ........................................................... 6
Remote Sensor (RTGR328N) ................................ 9
Getting Started.......................................................... 9
Batteries ............................................................... 9
Change Settings................................................... 10
Remote Sensor ....................................................... 10
Sensor Data Transmission ................................... 12
Search for Sensor ................................................ 12
Clock and Calendar ................................................ 12
Radio-Controlled Clock ........................................ 12
Set Clock.............................................................. 14
Switch Clock Display ............................................ 14
BAR916HG_EN_OP.indd 1
World Time Clock .................................................... 14
Alarms ..................................................................... 19
Set Daily Alarm..................................................... 19
Set Pre-Alarm....................................................... 19
Activate Alarm ...................................................... 20
Snooze ................................................................. 20
Barometer................................................................ 20
View Barometer Area ........................................... 20
Select Measurement Unit..................................... 20
View Barometer History ....................................... 20
Bar Chart Display ................................................. 21
Set Altitude ........................................................... 21
Weather Forecast ................................................... 21
Weather Forecast Icons ....................................... 21
UV Measurement .................................................... 22
New Additional UV Features ................................ 22
Temperature and Humidity .................................... 23
Select Measurement Unit..................................... 24
Select Sensor Channel ........................................ 24
Minimum / Maximum Records.............................. 24
Temperature and Humidity Trend......................... 24
Comfort Zone ....................................................... 25
Heat Index............................................................ 25
Backlight ................................................................. 25
1
5/8/06 11:20:24 AM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BAR916HG and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Oregon Scientific BAR916HG

  • Page 1: Table Of Contents

    Wireless Weather Station World Time Clock ............ 14 Alarms ..............19 with World Time Clock Set Daily Alarm............. 19 Model: BAR916HG Set Pre-Alarm............19 USER MANUAL Activate Alarm ............20 Snooze ..............20 CONTENTS Barometer..............20 Introduction .............. 3 View Barometer Area ........... 20 Product Overview .............
  • Page 2 Reset System ............25 Safety and Care ............26 Warnings ..............26 Troubleshooting ............. 26 Specifications ............27 About Oregon Scientific ........28 EU-Declaration of Conformity ......29 BAR916HG_EN_OP.indd 2 5/8/06 11:20:25 AM...
  • Page 3: Introduction

    INTRODUCTION Thank you for selecting the Oregon Scientific Wireless Weather Station with World Time Clock (BAR916HG). This powerful device bundles time keeping, weather monitoring, indoor and outdoor temperature and humidity readings, barometric trends and altitude adjustment, into a single tool you can use from the convenience of your home.
  • Page 4: Product Overview

    PRODUCT OVERVIEW FRONT VIEW 1. SNOOZE / LIGHT: Activate 8-minute snooze or backlight 2. LCD display 3. SEL: Switch areas 4. MODE: Change settings / display : Increase setting / activate radio-controlled clock : Decrease setting / deactivate radio- controlled clock 7.
  • Page 5: Back View

    BACK VIEW TABLE STAND AND WALL MOUNT To stand the unit on a table, twist the lock button (on the back of the unit) so that the two main unit segments are unlocked from each other. Then position the unit as shown below.
  • Page 6: Lcd Display

    LCD DISPLAY 1. Weather Forecast Area: Animated weather forecast. 2. Temperature / Humidity / Comfort Zone Area: Readings and trend lines; comfort zone; sensor channel number. 3. UVI / Barometer Area: UV level and barometric pressure bar chart; UV Index and barometric readings.
  • Page 7 Weather Forecast Area Temperature / Humidity / Comfort Zone Area 1. Selected Area icon 2. Temperature trend 3. Channel number (1-5) / reception status 1. Low battery icon for main unit 4. Low battery icon for remote sensor 2. Weather display 5.
  • Page 8 UVI / Barometer Area Clock / Alarm / Calendar Area 1. Pre-Alarm is set 2. Pre-Alarm display / Pre-Alarm setting 1. Barometric pressure is showing 3. Channel with RF clock reception is locked 2. UV is showing 4. RF clock reception icon 3.
  • Page 9: Remote Sensor (Rtgr328N)

    1. Signal reception REMOTE SENSOR (RTGR328N) 2. Channel number 1. LCD display 3. Low battery icon 2. LED status indicator 4. Time 3. Ventilation duct 5. Temp (°C or °F) 6. Humidity % 7. Temp / Humidity GETTING STARTED BATTERIES Batteries are supplied with this product: •...
  • Page 10: Change Settings

    To install the main unit batteries: 2. Most Areas have alternate display options (for example, Clock / Alarm or Barometer / UVI). Press MODE to switch options, or switch between clock and alarm. 3. Press and hold MODE for 2 seconds to enter setting NOTE Do not use rechargeable batteries.
  • Page 11: Set Up Thermo / Hygro Sensor (Rtgr328N)

    The RTGR328N Sensor collects temperature and To fold out the stand: humidity readings, and signals from official time-keeping organizations for the radio-controlled clock. SET UP THERMO / HYGRO SENSOR (RTGR328N) 1. Open the battery compartment with a small Phillips screwdriver. For best results: 2.
  • Page 12: Sensor Data Transmission

    SENSOR DATA TRANSMISSION Then, press and hold MEM and CH for 2 seconds. Data is sent from the sensor(s) every 60 seconds. The reception icon shown in the Temperature / Humidity Area NOTE If the sensor is still not found, check the indicates the status.
  • Page 13: Turn Radio-Controlled Clock On / Off

    you first set up the unit, and whenever you press RESET. The unit cannot reach the remote Once complete, the reception icon will stop blinking. sensor. To force a manual search for RF clock NOTE In addition to the local time and calendar display, you reception, press and hold SEARCH on the sensor can also select to display the corresponding time of 130 (RTGR328N) for 2 seconds.
  • Page 14: Set Clock

    SET CLOCK • Clock with day and date You only need to do this if you have disabled the radio- controlled clock, or if you are too far from a RF signal. When the World Time city is set, you can toggle between: •...
  • Page 15 CITY, COUNTRY CITY CODE TIME OFFSET SUMMER TIME START DATE SUMMER TIME END DATE Addis Ababa, Ethiopia No DST Adelaide, Australia Last Sunday in October Last Sunday in March Auckland, New Zealand 1st Sunday in October 3rd Sunday in March Ankara, Turkey Last Sunday in March Last Sunday in October...
  • Page 16 Cape Town, South Africa No DST Dhaka, Bangladesh No DST Damascus, Syria 1st April 1st October New Delhi, India No DST Detroit MI, USA 1st Sunday in April Last Sunday in October Dublin, Ireland Last Sunday in March Last Sunday in October Frankfurt, Germany Last Sunday in March Last Sunday in October...
  • Page 17 Melbourne, Australia Last Sunday in October Last Sunday in March Mexico City, Mexico 1st Sunday in April Last Sunday in October Managua, Nicaragua No DST Miami FL, USA 1st Sunday in April Last Sunday in October Milan, Italy Last Sunday in March Last Sunday in October Manama, Bahrain No DST...
  • Page 18 Singapore, Singapore No DST San Jose, Costa Rica No DST San Juan, Puerto Rico No DST Salt Lake City UT, USA 1st Sunday in April Last Sunday in October Sofia, Bulgaria Last Sunday in March Last Sunday in October Sao Paulo, Brazil 2nd Sunday in October 3rd Sunday in February Stockholm, Sweden...
  • Page 19: Alarms

    For example, if you set the alarm to 7:00 AM, and the ALARMS Pre-Alarm to 45 minutes, the Pre-Alarm will sound at This product has 2 alarms: The Daily Alarm and a 6:15 AM provided the outdoor temperature at Channel Pre-Alarm for snowy weather.
  • Page 20: Activate Alarm

    Barometric data is shown in 2 areas at the bottom of the ACTIVATE ALARM display. The upper area shows a 24-hour bar chart. The Navigate to the Clock Area, then press lower area shows current and historical readings. switch to Daily Alarm or Pre-Alarm view. To activate or deactivate the alarm, press When the alarm time is reached, the backlight will be on for 8 seconds and crescendo alarm will sound for 2...
  • Page 21: Bar Chart Display

    1. Navigate to the Barometer Area. 2. Press and hold HIST for 2 seconds. 3. Press to set the altitude in 10-metre increments (-100m to 2500m). 4. Press HIST to confirm. WEATHER FORECAST This product forecasts the next 12 to 24 hours of weather within a 30-50 km (19-31 mile) radius.
  • Page 22: Uv Measurement

    • Automatic calculation of acceptable UV exposure Cloudy times based on pre-set user profiles (4 users maximum). • UVI Danger Alert when UV Index reaches unsafe Clear (Night) levels. Partly Cloudy (Night) UV data is shown in the same area as the Barometer. Press SEL to navigate to the Barometer Area, then press MODE to display the UV icon and data.
  • Page 23: Temperature And Humidity

    2. Press CH to select user 1-4. countdown. The remaining user UV exposure time will display and the will flash. 3. Press and hold MODE for 2 seconds to enter the Skin Type Setting Mode of the selected user. 7. When the countdown has reached “0”, an alarm will sound for 2 minutes.
  • Page 24: View Temperature And Humidity Area

    • To auto-scan between sensors, press and hold CH Data is collected and displayed approximately every for 2 seconds. Each sensor’s data will be displayed 60 seconds. for 3 seconds. • To end auto-scan, press CH or MEM with the VIEW TEMPERATURE AND HUMIDITY AREA Temperature / Humidity Area selected.
  • Page 25: Comfort Zone

    will show next to the Area. COMFORT ZONE 2. Press MODE to reach the Heat Index display. The Comfort Zone indicates how comfortable the 3. Press CH to select the desired channel. climate is, based on current temperature and humidity measurements.
  • Page 26: Safety And Care

    SAFETY AND CARE TROUBLESHOOTING Clean the product with a slightly damp cloth and alcohol PROBLEM SYMPTOM REMEDY free, mild detergent. Avoid dropping the product or Barometer Strange Set altitude / unit placing it in a high-traffic location. readings Calendar Strange Change language WARNINGS date /...
  • Page 27: Specifications

    Resolution SPECIFICATIONS Comfort 40% to 70% Main Unit Dimensions Memory Min / max L x W x H 195 x 26 x 192 mm (7.6 x 0.8 x 7.5 inches) Barometer Weight 578 grams (20.4 ounces) Unit mb / hPa or inHg without battery Resolution 1 mb (0.03 inHg)
  • Page 28: About Oregon Scientific

    Hour format 12hr AM/PM (MSF format) ABOUT OREGON SCIENTIFIC 24hr (DCF format) Visit our website (www.oregonscientific.com) to learn Calendar DD / MM or MM / DD; more about Oregon Scientific products such as digital Day of the week in 1 of cameras;...
  • Page 29: Eu-Declaration Of Conformity

    EU-DECLARATION OF CONFORMITY Hereby, Oregon Scientific, declares that this Wireless Weather Station with World Time Clock model BAR916HG is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A copy of the signed and dated Declaration of Conformity is available on request via our Oregon Scientific Customer Service.

Table of Contents