Specifications - Friedrich M2404ER Service And Parts Manual

Thru-the-wall series
Table of Contents

Advertisement

1.3 SPECIFICATIONS

1.3.1 FOR US08B10A, US10B10A, US12B10A
ITEMS
POWER SUPPLY
CAPACITY
INPUT
RUNNING CURRENT
E.E.R
REFRIGERANT (R-22) CHARGE(g)
OPERATING
INDOOR (°C)
TEMPERATURE
OUTDOOR (°C)
EVAPORATOR
CONDENSER
FAN, INDOOR
FAN, OUTDOOR
FAN SPEEDS, FAN/COOLING
FAN MOTOR
OPERATION CONTROL
ROOM TEMP. CONTROL
AIR DIRECTION CONTROL
CONSTRUCTION
COMPRESSOR
PROTECTOR
FAN MOTOR
POWER CORD
DRAIN SYSTEM
NET WEIGHT
DIMENSION
(W x H x D)
SLEEVE DIMESION
(W x H x D)
SLEEVE DEPTH
WITH FRONT GRILLE
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
MODELS
US08B10A
(Btu/h)
8,000
(W)
830
(A)
7.5
(Btu/w.h)
9.6
540g(19.1OZ)
2 ROW 12STACKS
PROPELLER TYPE FAN WITH SLINGER-RING
6 POLES
ATTACHMENT PLUG(CORD-CONNECTED TYPE, LCDI)
(lbs/kg)
73/33
(inch)
(mm)
(inch)
(mm)
(inch)
(mm)
US10B10A
1Ø, 115V,60Hz
9,800
1,110
10.2
8.8
475g(16.8OZ)
26.7(DB) 19.4(WB)
35(DB) 23.9(WB)
3 ROW 12STACKS
2 ROW 17STACKS, L-BENDING TYPE
TURBO FAN
3/3
ELECTRIC
THERMISTOR
VERTICAL LOUVER(RIGHT & LEFT)
HORIZONTAL LOUVER(UP & DOWN)
TOP-DOWN
EXTERNAL OVERLOAD PROTECTOR
INTERNAL THERMAL PROTECTOR
2.3m (3WIRES WITH GROUNDING)
SPLASHED BY FAN SLINGER
78/35
13
24 x 14
/
x 20
32
610 x 366 x 499
7
17
25
/
x 15
/
x 16
8
32
656 x 394 x 425
20
1
/
20
521
- 3 -
US12B10A
11,700
1,250
11.4
9.4
485g(17.1OZ)
4POLES
80/36
3
/
32
23
/
32
LGE Internal Use Only
REMARK
LOUVERED-FIN TYPE
OPTIONAL
PART

Advertisement

Table of Contents
loading

This manual is also suitable for:

Us08b10aUs10b10aUs12b10a

Table of Contents