Refrigeration Cycle; Condenser; Evaporator; Capillary Tube - Friedrich M2404ER Service And Parts Manual

Thru-the-wall series
Table of Contents

Advertisement

2.4 REFRIGERATION CYCLE

CAUTION
Discharge the refrigerant system using a Freon
Recovery System.
Install a valve for the recovery, before venting
the Freon, remove the valve when finished.

2.4.1 CONDENSER

1. Remove the cabinet. (Refer to section 2.1.2)
2. Remove the brace.
(Refer to section 2.2.1)
3. Remove the 7 screws which fasten the condenser.
4. After discharging the refrigerant completely into a
Freon
TM
Recovery System, unbraze the
interconnecting tube at the condenser
connections.
5. Remove the condenser.
6. Re-install the components by referring to the notes
– on pages 13-14. (See Fig. 15)

2.4.2 EVAPORATOR

1. Remove the cabinet. (Refer to section 2.1.2)
2. Discharge the refrigerant completely – into a
Freon
TM
Recovery System.
3. Remove the 2 screws which fasten the evaporator
at the left side and the right side.
4. Move the evaporator sideward carefully and then
unbraze the interconnecting tube at the evaporator
connectors.
5. Remove the evaporator.
6. Re-install the components by referring to the notes
– on pages 13-14. (See Fig. 16)

2.4.3 CAPILLARY TUBE

1. Remove the cabinet. (Refer to section 2.1.2)
2. After discharging the refrigerant completely – into
a Freon
TM
Recovery System, unbraze the
interconnecting tube at the capillary tube.
3. Remove the capillary tube.
4. Re-install the components by referring to the notes
– on page 13-14.
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
TM
Figure 15
Figure 16
- 10 -
LGE Internal Use Only

Advertisement

Table of Contents
loading

This manual is also suitable for:

Us08b10aUs10b10aUs12b10a

Table of Contents