Installation
INSTALLATION
CAUTION
We strongly
recommend
the removal of the
old wall sleeve and the installation
of a new
LGE Wall Sleeve,
If you decide to keep the existing wall sleeve,
you have to redirect the louvers at the back of
the wall
sleeve illustration. The use of pliers is
recommended.
If you DO NOT redirect, you run
the risk of poor performance
or product failure.
This is not covered
under the terms of the
LGE
warranty.
• Pick a location
which will allow the conditioned
air
to blow into the area you want. Good installation
with special attention to the proper position
of the
unit will lessen the chance that service will be
needed.
ITEMS
IN INSTALLATION
HARDWARE
You may not need all parts in the kit. Discard
unused parts
ITEM (inches)
Plastic grille
Horizontal
Insulation
Strips
Around Insulation
Strips
Support
Block
Baffle
Shim
Trim Frame
Washer Screw
Nuts(Plastic)
Grille Rear
263/4 x 161/2
13/8x 5/8 x 273/16
13/8x 13/8x 27%'t6
13/8x 3/4 x 611/2
13/8x 13/8x 611/2
13/4 X 13/8 X 45/'16
1 4 x 41/2 x %
13xl
x3/4
Qty.
1
1
1
1
1
2
1
2
2
4
4
1
HOW TO INSTALL
E_
Identify the existing wall sleeve before
installing the unit from the listed below.
Brand
White-Westinghouse
Frigidaire
Carrier (52F series)
General
Electric
iHotpoint
Wall Sleeve Dimensions (inches)
Width
Height
25-1/2
15-1/4
26
15-5/8
Whirlpool
25-7/8
16-1/2
FeddersiEmerson
27
16-3/4
LGE
25-7/8
15-17/32
Emerson/Fedders
26-3/4
15-3/4
Carrier (51S Series)
25-3/4
16-7/8
Friedrich
27
16-3/4
Depth
16, 17-1/2
or 22
16-7/8
17-1/8
or 23
16-3/4
or 19-3/4
16-23/32
15
18-5/8
16-3/4
All wall sleeves used to mount the new Air
Conditioner
must be in sound structural
condition
and have a rear grille that securely
attaches to
sleeve, or rear flange that serves as a stop for the
Air Conditioner,
_
emove old air conditioner
from existing wall
sleeve.
_
lean the interior of an existing sleeve.
(Do not disturb seals.)
u
all sleeve must be securely fastened in wall
before installing the air conditioner.
Use the
nails or screws through sleeve into wall, if
needed. Repaint sleeve if needed.
_
repare the wall sleeve for installation
of the
unit. If you plan to use your existing wall
sleeve, and it is not LGE, use procedure
B or
C below.
Procedure
A
C
Brand
LGE
White-Westinghouse
Frigidaire
Carrier
(52F series)
General
Electric
iHotpoint
Whirlpool
Carrier
(51S series)
Fedders/Emerson
EmersoniFedders
Friedrich
Depth(inches)
16-23/32
16, 17-1/2
or 22
16-7/8
17-1/8 or 23
18-5/8
16-3/4
or 19-3/4
15
16-3/4
r_
Install
unit into wall sleeve.
new
& CAUTION
When installation
is completed,
replacement
unit
MUST have a rearward
slope as shown. To achieve
1.4" slope, remove the backing from the 11-13/16"
shim strips and attach them as shown below in Fig.
3. Place the higher portion
of shim to the front of
the rib on base of wall sleeve.
1"h_gl_l--1
113/4"
High
UNIT
Wall Sleeve
SHIM
PLACEMENT
UNIT INSTALLATION
FIG. 3
12
Room Air Conditioner

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lt1230h