TERMINAL
R1
House Telephone Ring (Grey).
R
Telephone Ring (Red).
T
Telephone Tip (Green).
T1
House Telephone Tip (Brown).
EARTH
Earth Ground. Connect to a cold water pipe or a 6 to 10 foot driven rod.
AC
AC input. Connect to a 16.5V 25, 40 or 50 VA Class ll U.L. approved transformer.
If used as a siren output(default), the speaker rating should be 15 watt at 8 or 16 ohm, or 30/40
watt at 4, 8, or 16 ohms. If voltage output is selected in location 37, this output becomes voltage
BELL + &
output, 12VDC, 1 Amp maximum load. NOTE: A 3.3K Ω resistor may be required across the
BELL -
bell terminals when a 12 VDC siren is used. If no resistor is used, you may experience
voltage leakage into the siren which will cause these devices to output a small signal.
Connect to the data terminal on the keypads and the expanders. Maximum number of devices
KP DATA
(keypads + expanders) is 32. See AMaximum Wire Run@ chart below.
KP COM
Connect to the Common terminal on the keypads and the expanders.
Connect to the POS terminal on the keypads and the expanders. This terminal and AUX PWR +
KP POS
are limited to 1 amp total current when added together.
Smoke detector power 12VDC, 1.5 amps maximum (For those jurisdictions which allow the
SMOKE+
Priority zone to be used with smoke detectors.)
COM
Connect negative wire of powered devices such as motion detectors and smoke detectors.
Connect positive wire of all powered devices except smoke detectors and keypads. This terminal
AUX PWR+
and KP POS are limited to 1 amp total current when added together.
Connect to one side of zone 8 loop. Connect the other side to com terminal. Open or short causes
alarm. Zone 8 may be used for a two-wire smoke detector using a 680 Ω E.O.L. resistor. W3
ZONE 8
must be set for two-wire smoke detector loop. For normal zone operation, W4 must be set.
COM
Common (-) terminal for zones 7 & 8. (See the wiring diagram for examples.)
Connect to one side of zone 7 loop. Connect the other side to COM terminal. Open or short
ZONE 7
causes alarm.
ZONE 6 -
Connect as described for zones 7 & 8. Only zone 8 can be a two-wire zone. (See the wiring
ZONE 1
diagram for examples.)
Connect negative lead of low current device [relay, LED(install 1kΩ resistor in series with LED),
AUX 4 –
etc.]. Connect positive lead of device to AUX PWR +. Current is limited to 50mA when output is
AUX 1
negative, and 250FA when output is positive.
(Note: These numbers are for one keypad at the end of the wire. When connecting more than one keypad to the
Length in feet
250
500
1000
1500
2500

TERMINAL DESCRIPTION

NETWORX KEYPAD MAXIMUM WIRE RUN
end of the wire, a higher gauge wire will be required.)
WHEN CONNECTED TO NX-8
Wire Gauge
24
20
18
16
14
Page 55
DESCRIPTION
WHEN CONNECTED TO NX-320
Wire Gauge
22
18
16
14